Target: Mass gas flow measurement in the flow channel
Model: F1031V
Detection range: 100, 150, 200, 300SLM
Detection principle: Principles of thermodynamics
Characteristics: High accuracy, quick response, good repeatability

F1031V Manual download
Get Price Whatsapp

Description

The F1031V flow sensor uses the thermodynamic principle to detect flow rate of the gas medium in the flow channel, with good precision and repeatability. Temperature sensors are built-in and every one product is calibrated for temperature compensation. At the same time, it has linear analog voltage output, convenient to use.

Application

  • Intensive care
  • Medical or home use ventilator
  • Portable ventilator/meter

Features

  • Latest MEMS Sensor chip technology
  • High accuracy, quick response, good repeatability
  • Detection micro flow accurately
  • It is calibrated completely and temperature compensated

Specifications

Model F1031V
Measuring Range① 100, 150, 200, 300SLM②
  Min Typical Max Unit
Full Scale Output 4.34 4.50 4.66 V
Zero Output 0.45 0.5 0.55 V
Output Impedance - 1000 - Ω
Working Voltage 4.95 5.0 14.0 V
Working Current - 25 - mA
Accuracy - ±2.5 ±4 %F.S
Repeatability - ±0.5 ±1 %F.S
Output Drift   0.12   %/℃
Signal noise - 10 - mV(Vrms)
Resistance - 120 - Pa/60SLM
Power consumption - 125 - mW/5V
Working pressure - - 100 kPa
Response Time③ - 10 - ms
Working Temp.④ -25   65
Storage Temp. -40   90
Note:
①The measuring range within 20-300SLM. 
②SLM means standard liter per minute. Standard-state: gas temperature is 20℃ and pressure is 101.325 kPa. The testing environment is room temperature and clear air.
③The response time could be customized for 15-1000ms. 
④The temperature compensation is for the tem. range of 0-50℃ and the compensation performance can’t be ensured beyond the temperature range.

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory. However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER

RELATED PRODUCTS