ZH10 Compact 4-in-1 Air Quality Sensor Module
ZH10 Compact 4-in-1 Air Quality Sensor Module
  • PM2.5,VOC,Temperature,Humidity
  • Read More
Multi-in-One Sensor Module ZPHS01C
Multi-in-One Sensor Module ZPHS01C
  • PM2.5, CO2, CH2O, TVOC,Temperature&Humidity
  • CO2: 400~5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%)
  • Read More
Multi-in-One ZPHS01B Sensor Module
Multi-in-One ZPHS01B Sensor Module
  • CO2. PM2.5. CH2O. O3. CO. TVOC. NO2. Temperature. Humidity
  • See Manul
  • Read More
4-in-1 Industrial Gas Detection Module  ZCE04B
4-in-1 Industrial Gas Detection Module ZCE04B
  • CH4(1%LEL), CO(1ppm), H2S(1ppm), O2(0.1%LEL)
  • 0-100%LEL ,0-1000ppm ,0-100ppm ,0-30%LEL
  • Read More
Atmospheric Monitoring Sensor Module ZEHS04
Atmospheric Monitoring Sensor Module ZEHS04
  • CO, SO2, NO2, O3 (Scalable PM2.5, PM10, Temperature, Humidity)
  • See manual
  • Read More
ZPHS01 Multi-in-One Sensor Module (HCHO version)
ZPHS01 Multi-in-One Sensor Module (HCHO version)
  • CO2, PM2.5, CH2O, VOC, Temperature, Humidity
  • CO2: 0-5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%)
  • Read More

Help you compare our sensors

Table Overview for Winsen Multi-in-one Module

Unsure which sensor to choose, please leave your infomation or email us

Modle Detection principle Characteristics Target gas Detection range Size

ZH10
Laser scattering principle Good consistency,Miniature size,Low power consumption,Compatible with VOC and temperature and humidity output. PM2.5,VOC,Temperature,Humidity 38×35×12mm(L×W×H)

ZPHS01C
Module, electrochemical, semiconductor VOC sensor, laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor This module integrates Electrochemical formaldehyde, Semiconductor VOC sensor, Laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor. PM2.5, CO2, CH2O, TVOC,Temperature&Humidity CO2: 400~5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%) 62.5mm (L) x 61mm(W) x 25mm(H)

ZPHS01B
Module See Manul CO2. PM2.5. CH2O. O3. CO. TVOC. NO2. Temperature. Humidity See Manul 135 x 50 x 26.2mm (L x W x H)

ZCE04B
Module,catalytic, electrochemical The detection of toxic and harmful gas and combustible gas in special places will give an alarm when the concentration exceeds the standard to remind people to evacuate CH4(1%LEL), CO(1ppm), H2S(1ppm), O2(0.1%LEL) 0-100%LEL ,0-1000ppm ,0-100ppm ,0-30%LEL 41×41×21.6

ZEHS04
Module, electrochemical Urban atmospheric environmental monitoring; Unorganized emissions of pollution monitoring at factory sites; Portable instruments, air quality monitoring equipment, and smart home equipment. CO, SO2, NO2, O3 (Scalable PM2.5, PM10, Temperature, Humidity) See manual 12cm*10cm*6cm (L*W*H)

ZPHS01
Module, electrochemical, semiconductor VOC sensor, laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor This module integrates Electrochemical formaldehyde, Semiconductor VOC sensor, Laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor. CO2, PM2.5, CH2O, VOC, Temperature, Humidity CO2: 0-5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%) Length×Width: 72x61

ARE YOU LOOKING FOR SENSOR

Not sure which sensor is right?

Get a free initial consultation right now

WHAT WE DO

Multi-in-one Module Knowledge

Keeping low CO2 level is important for human health, which not only means that the current environment has sufficient fresh air, but also greatly reduce the risk of building syndrome. Winsen CO2 sensor meets RESET standard, which is widely used in control panels or thermostats for HVAC systems.

Leading gas sensing Solution supplier

Our Hot Products

ANY QUESTIONS?

Frequent Asked Questions

Professional manufacturer of gas sensors, global sensing solutions provider with over 30 years of experience. Top quality guarantee, Excellent service, Customized products, Fast delivery!

Reference lead times: 1-15 days after receiving deposit depending on volume. The actual lead time can be confirmed with Winsen Order Processing Dept.

Winsen will recommend the most appropriate way of transportation (express, air, sea, train, etc.) according to customer's requirement on cost and time.

T/T, Paypal, West Union, Credit Card, etc.

MOQ is different depending on product models. Please contact Winsen sales for details.

Customer LOGO and packing design are acceptable.
Customized design and function will be provided without extra charge (including molding fee).

Sample order is acceptable and the fees will be borne by buyer.

Winsen has a complete and strict flow for offline sensors: aging-reject defective-sampling inspection-issue reports-finished ingoing...outgoing.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

ppm: parts per million
ppb: parts per billion
VOL: volume ratio
LEL: lower explosive limit
NDIR: Non-Dispersive Infra-Red

CONTACT US

LET'S TALK

Request Consultation