
ZH08 Laser dust sensor
- PM1.0, PM2.5, PM10
- Read More

ZH07 Laser dust sensor
- PM2.5
- 0-1000μg/m³
- Read More

ZH06-IV Laser dust sensor
- PM2.5
- 0-1000μg/m³
- Read More

ZH06-III Laser dust sensor
- PM2.5
- 0-1000μg/m³
- Read More

ZH06-II Laser dust sensor
- PM2.5
- 0-1000μg/m³
- Read More

ZH06-Ⅰ Laser dust sensor
- PM2.5
- 0-1000μg/m³
- Read More

ZH03B Laser Dust Sensor Module
- PM2.5
- 0-1000μg/m³
- Read More

ZPH04B Particles Sensor
- PM2.5
- 0-500ug/m3
- Read More

ZPH02 Particles and VOC Sensor
- Dust PM2.5, VOC
- VOC is 5 level Output
- Read More

ZPH01 Air-quality and Particles Sensor
- VOC,PM2.5
- 15000 particles /283ml
- Read More
Help you compare our sensors
Table Overview for Winsen Dust sensor
Unsure which sensor to choose, please leave your infomation or email us
Modle | Detection principle | Characteristics | Target gas | Detection range | Size |
---|---|---|---|---|---|
![]() ZH08 |
Mie Scattering Theory | Good consistency,Real time response | PM1.0, PM2.5, PM10 | 58.5×44.5×14.8mm(L×W×H) | |
![]() ZH07 |
Mie Scattering Theory | Good consistency,Real time response,Low power consumption | PM2.5 | 0-1000μg/m³ | 48×40×12.5mm(L×W×H) |
![]() ZH06-IV |
Mie Scattering Theory | Good consistency,Real time response,Accurate data | PM2.5 | 0-1000μg/m³ | 47×37×12.2mm(L×W×H) |
![]() ZH06-III |
Mie Scattering Theory | Good consistency,Real time response,Accurate data | PM2.5 | 0-1000μg/m³ | 47×37×12.6mm(L×W×H) |
![]() ZH06-II |
Mie Scattering Theory | Good consistency,Real time response,Accurate data | PM2.5 | 0-1000μg/m³ | |
![]() ZH06-Ⅰ |
Mie Scattering Theory | Good consistency,Real time response,Accurate data | PM2.5 | 0-1000μg/m³ | 47×37×12.2mm(L×W×H) |
![]() ZH03B |
Mie Scattering Theory | Good consistency, Real time response | PM2.5 | 0-1000μg/m³ | 50x32.4x21mm(LxWxH) |
![]() ZPH04 |
Mie Scattering Theory | Good Stability for long time,Easy to install and use | PM2.5 | 59.5×44.5×20mm(L×W×H) | |
![]() ZPH04B |
Mie Scattering Theory | Good Stability for long time,Easy to install and use | PM2.5 | 0-500ug/m3 | 59×45×20mm(L×W×H) |
![]() ZPH02 |
ZPH02 Particles and VOC " Module,semiconductor, NDIR dust | Dust sensor and VOC sensor integrated, the sensor has been aged, debuged, calibrated before delivery and has good consistency and high sensitivity | Dust PM2.5, VOC | VOC is 5 level Output | 59.5×44.5×17 |
![]() ZPH01 |
High sensitivity, good stability for long time, calibrated before delivery, built-in heater to snift air automatically. | VOC,PM2.5 | 15000 particles /283ml | 59.47×44.5×20mm(LxWxH) |
- 0086-371-67169097
- sales@winsensor.com
- Mon - Fri 9am - 6pm
ARE YOU LOOKING FOR SENSOR
Not sure which sensor is right?
Get a free initial consultation right now
WHAT WE DO
Dust sensor Knowledge
Keeping low CO2 level is important for human health, which not only means that the current environment has sufficient fresh air, but also greatly reduce the risk of building syndrome. Winsen CO2 sensor meets RESET standard, which is widely used in control panels or thermostats for HVAC systems.