Model: WPAS02
Detection principle: MEMS piezoresistive pressure sensing
Characteristics: SOP6 package, gauge pressure measurement, low cost, fast response, high reliability and customizable pressure ranges and output methods.
Standard encapsulation: SOP6
Output signal: Millivolt bridge output
Measurement range: 0~10kPa, 0~20kPa, 0~40kPa, 0~100kPa, 0~200kPa
Response time: ≤1ms, Up to 90%FS
Pressure Range: -100kPa~200kPa
Pressure Reference: Gauge Pressure
Working Temperature: -30℃~100℃

WPAS02 Manual download
Get Price Whatsapp

Description

WPAS02 is a plastic package pressure sensor manufactured using a high-precision MEMS pressure-sensitive chip and mature production processes. Its standard pin and pressure-port structure supports convenient integration into OEM pressure measurement modules.

The sensor is intended for gauge, vacuum and negative pressure measurement of dry and non-corrosive gases. Different measuring ranges and output methods can be customized according to customer requirements.

Application

  • Process control systems
  • Pressure calibration instruments
  • Blood pressure monitors
  • Ventilators
  • Oxygen concentrators
  • Patient monitors
  • Environmental monitoring
  • Consumer products
  • Massage chairs
  • Massagers
  • Air mattresses
  • Tire pressure gauges
  • MAP systems
  • Power steering systems
  • Brake assist systems
  • Vacuum packaging machines
  • Vacuum blenders
  • Vacuum breakers
  • Vacuum food storage containers
  • Vacuum pumps

Features

  • SOP6 plastic package
  • High-precision MEMS pressure-sensitive chip
  • Standard pressure-port structure
  • Suitable for module assembly
  • Gauge pressure measurement
  • Vacuum and negative pressure measurement
  • Low-cost OEM solution
  • Fast response
  • High reliability
  • High vibration resistance
  • High impact resistance
  • Customizable pressure ranges
  • Customizable output methods

Specifications

Detection Range -100kPa~0kPa…10kPa…200kPa
Pressure Type Gauge Pressure
Excitation (5±0.005)V
Impedance 4kΩ~6kΩ
Electronic Connection PINS; copper plated with silver
Working Temperature -30℃~100℃
Storage Temperature -40℃~125℃
Response Time ≤1ms, Up to 90%FS
Detection Medium Dry and non corrosive gas
Mechanical Vibration 20g(20~5000Hz)
Impact 100g(10ms)
Lifespan 10×106 pressure cycles
Overload Pressure 200%FS
Burst Pressure 300%FS
Non-linearity ≤10kPa: Min -0.5%FS, Typical ±0.3%FS, Max 0.5%FS; >10kPa: Min -0.3%FS, Typical ±0.15%FS, Max 0.3%FS
Hysteresis Min: -0.3%FS; Typical: ±0.15%FS; Max: 0.3%FS
Repeatability Min: -0.3%FS; Typical: ±0.15%FS; Max: 0.3%FS
Zero Point Output -40mV~+40mV
Full-range Output Coefficient ≤10kPa: 35~65mV, Typical 50mV; 20kPa: 35~50mV, Typical 40mV; 40kPa: 60~90mV, Typical 75mV; ≥100kPa: 70~110mV, Typical 90mV
Zero Temperature Coefficient Min: -0.05%FS/℃; Typical: ±0.02%FS/℃; Max: 0.05%FS/℃
Full-range Temperature Coefficient -0.06%FS/℃
Heat Hysteresis Min: -0.075%FS; Typical: ±0.05%FS; Max: 0.075%FS
Long-term Stability Min: -0.3%FS/Year; Typical: ±0.2%FS/Year; Max: 0.3%FS/Year
Package SOP6

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER