Model: WPAS09
Detection principle: MEMS
Characteristics: Absolute pressure measurement, I²C output, low power consumption
Standard encapsulation: 2.0 × 2.5 × 1.2mm³
Output signal: I²C digital pressure and temperature output
Pressure Range: 0.1~2MPa Absolute Pressure
Pressure Reference: Absolute Pressure
Working Temperature: -40~125℃


Get Price Whatsapp

Description

The WPAS09 series is a digital pressure sensor designed for portable pressure-measurement and consumer applications. It combines a MEMS silicon piezoresistive pressure sensor core with a digital compensation signal-conditioning circuit and a 24-bit ΔΣ ADC.

The sensor uses an 8-pin LGA metal-cap package and is internally potted for waterproofing. Factory calibration coefficients stored in non-volatile memory are used to compensate pressure, temperature, zero point, sensitivity and linearity. The I²C interface allows direct integration with an MCU. 

Application

  • Handheld air pump pressure detection
  • Manual pressure gauges
  • Portable tire pressure monitoring systems
  • Engine pressure control systems
  • Pneumatic pressure monitoring systems
  • Air compressors
  • Home appliances
  • Battery-powered pressure instruments
  • Portable pressure measurement devices 

Features

  • Digital absolute pressure measurement
  • MEMS silicon piezoresistive sensing
  • High-resolution 24-bit ADC
  • I²C digital interface
  • Ultra-low power consumption
  • Low standby current
  • Factory-calibrated compensation
  • Integrated temperature measurement
  • Internal waterproof potting
  • Compact 8-pin LGA package
  • Metal cap package
  • Suitable for battery-powered portable devices
  • Selectable oversampling rates
  • Optional IIR filtering
  • RoHS compliant
  • Halogen-free 

Specifications

Measuring Range 0.1~2MPa, Absolute Pressure, as stated on the characteristic page
Operating Pressure Range 100~2000hPa, as stated in the technical datasheet
Supply Voltage 1.8~3.6V
Operating Current Typical 5.4μA at 1Hz data output rate and minimum oversampling rate
Peak Current During Pressure Measurement Typical 760μA
Current During Temperature Measurement Typical 541μA
Standby Current Typical 0.1μA; Max 0.3μA at 25℃
General Accuracy ±1%FS at 100~2000hPa and 0~60℃
Absolute Accuracy Typical ±6.8kPa at 0.1~2MPa and 0~60℃, as stated on the characteristic page
Temperature Absolute Accuracy ±0.5℃ at 25℃; ±1.0℃ from 0~60℃
Long-term Stability TBD over 12 months
Reflow Soldering Drift -0.5~+1Pa
Sampling Rate Min 157Hz; Typical 182Hz; Max TBD
Operating Temperature -40~125℃
Compensation Temperature 0~60℃
Storage Temperature -40~150℃
Maximum Overpressure 3mPa, as printed in the absolute maximum rating table
ESD Level ±2kV, Human Body Model
Digital Interface I²C, standard and fast modes
I²C Address 7-bit address 0x78
ADC 24-bit ΔΣ ADC
Package 8-pin LGA, metal cap
Package Size 2.0 × 2.5 × 1.2mm³
Protection Internally potted for waterproofing
Compliance RoHS compliant, halogen-free

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com