Model: WPAS13
Detection principle: MEMS
Characteristics: Differential pressure measurement, digital compensation, I²C interface
Standard encapsulation: 10.26 × 7.52 × 10.30mm
Output signal: I²C digital differential pressure output
Resolution and accuracy: Accuracy ±1%FS; 24-bit ADC
Pressure Range: -100~100kPa
Pressure Reference: Differential Pressure
Working Temperature: -5~65℃


Get Price Whatsapp

Description

The WPAS13 series is a digital micro differential pressure gas sensor based on a MEMS piezoresistive sensing core and a high-performance signal-conditioning circuit. The conditioning chip digitally compensates temperature linearity, zero bias and sensitivity.

The circuit includes a 24-bit Σ-Δ ADC to provide a high-precision pressure output. The sensing core and conditioning circuit are integrated into a dual-nozzle housing that reduces environmental influence on the output. Its JEDEC-compliant SOIC-16 surface-mount package supports PCB assembly.

Application

  • Sleep apnea monitoring
  • Oxygen concentrators
  • Negative pressure wound therapy
  • Airflow monitors
  • Gas flow meters
  • HVAC systems
  • Pneumatic instruments
  • Pressure switches
  • Biosafety cabinets
  • Airflow measurement
  • Liquid-level measurement
  • Consumer electronics
  • Medical respiratory equipment
  • Industrial differential pressure monitoring

Features

  • MEMS piezoresistive differential pressure sensing
  • Digital temperature compensation
  • Digital linearity compensation
  • Digital zero-bias compensation
  • Digital sensitivity compensation
  • High-resolution 24-bit ADC
  • I²C digital interface
  • Low average current
  • Low standby current
  • Dual-nozzle pressure connection
  • Compact SOIC-16 surface-mount package
  • High-precision pressure output
  • Customizable measuring ranges
  • RoHS compliant
  • Halogen-free

Specifications

Normal Pressure Range -0.5~0.5kPa / -1~1kPa / -2~2kPa / -4~4kPa / -10~10kPa / -100~100kPa
Optional Pressure Range 0~0.5kPa / 0~1kPa / 0~2kPa
Supply Voltage Min 1.8V; Typical 3.3V; Max 3.6V
Operating Current Typical 1.5mA
Standby Current Typical 100nA
Average Current Typical 5μA at 1Hz
ADC 24-bit
Accuracy ±1%FS
Response Time Min 1.54ms; Typical 2.5ms; Max 42.18ms
Working Temperature -5~65℃
Storage Temperature -40~125℃
Temperature Accuracy 1℃
Digital Interface I²C
Pressure Measurement Differential Pressure
Package JEDEC-compliant SOIC-16 surface-mount package with dual nozzles
Dimensions 10.26 × 7.52 × 10.30mm
Compliance RoHS compliant, halogen-free

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER

RELATED PRODUCTS