| Model: | ZW-HC101 |
| Detection range: | 0.01~20μS/cm |
| Detection principle: | Electrochemistry |
| Characteristics: | Intelligent algorithms, electromagnetic interference resistance, CAN output, excellent repeatability, excellent stability and long service life. |
| Output signal: | CAN / Analog Quantity, Customizable |
| Resolution and accuracy: | Resolution 0.01μS/cm; Accuracy ±1.5% F.S. |
| Pressure Range: | Operating Pressure <0.6MPa |
| Working Temperature: | -40℃~95℃ |
Get Price Whatsapp
Description
ZW-HC101 is an automotive online conductivity sensor designed for liquid conductivity monitoring in hydrogen fuel-cell engine thermal-management systems.
The sensor generates an excitation signal between its internal and external electrodes and measures the corresponding electrical signal. An automotive-grade intelligent chip, high-precision circuitry and software algorithms convert the measurement into a digital conductivity output.
Application
- Specialized Antifreeze for Automotive Fuel Cells
Features
- Intelligent algorithms
- Electromagnetic interference resistance
- CAN output
- Excellent repeatability
- Excellent stability
- Long service life
- High-resolution conductivity measurement
- IP68 protection
- IP6K9K protection
- Customizable analog output
Specifications
| Detection Principle | Electrochemistry |
| Detection Range | 0.01~20μS/cm |
| Resolution | 0.01μS/cm |
| Detection Accuracy | ±1.5% F.S. |
| Operating Voltage | DC 18~32V |
| IP Rating | IP68 / IP6K9K |
| Operating Temperature | -40℃~95℃ |
| Operating Pressure | <0.6MPa |
| Output Mode | CAN / Analog Quantity, Customizable |
* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.
Technical Support:
Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.
The sensors don't have sleeping mode. It can be set in program if needed.
All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.
The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.
However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.
15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.
Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.
Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.
Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com
Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.