Target: Alcohol
Model: ZE321
Detection range: 0 ~ 2mg/l
Characteristics: Highly accurate detection, Fast response, Stable and reliable
Output signal: UART(5V TTL)

ZE321 Manual download
Get Price Whatsapp

Description

Automotive Alcohol Module is a module designed to detect the alcohol content in the driver's exhaled gas. By accurately measuring the alcohol content, the module can effectively prevent drunk driving behaviors, thus safeguarding road traffic safety and the safety of people's lives and properties. The module adopts an electrochemical fuel cell type alcohol sensor, together with an on-board temperature sensor to realize temperature compensation and ensure the accuracy and reliability of the measurement results. In addition, the module also integrates a pressure sensor, which can realize the blowing action detection to further ensure the authenticity of the measurement, and the measurement data can be transmitted through the serial signal, which is convenient to integrate with the electronic control system of the vehicle.

The automotive alcohol module works based on the electrochemical sensor principle. When the built-in pressure sensor detects the exhaled gas flowing through the pipe at a specific flow rate, the solenoid valve responds quickly and inhales a quantitative sample of the gas, and the sensor activates detection simultaneously. Alcohol and oxygen in the gas undergo a redox reaction within the sensor, releasing an electrical charge to form a current signal. The module detects the current intensity through the circuit, and determines the alcohol concentration after processing by the algorithm, realizing the accurate detection of breath alcohol content.

Application

  • Environmental detection: Air quality monitoring stations, intelligent furniture equipment.
  • Industrial safety: Alcohol gas alarm system, portable detector.
  • Medical and healthcare: Breath analysis equipment (alcohol detection).
  • Traffic safety monitoring: Alcohol testing for drivers of vehicles in public transportation, logistics transportation, corporate fleets, personal vehicles, ports, mines and construction sites.

Features

  • Highly accurate detection: Using advanced electrochemical sensor technology has extremely high sensitivity and accuracy to alcohol.
  • Fast response: Able to complete the detection of alcohol concentration in a short time to ensure driving safety.
  • Stable and reliable: Characterized by long life, high accuracy, high repeatability and high stability, applicable to various complex environments.
  • Easy to install: The module is compact in design and easy to install, and can be seamlessly integrated with the vehicle.
  • Intelligent control: Supporting a variety of communication protocols and output methods, it is easy to integrate with other in-vehicle equipment.
  • Low power consumption: Reasonable design, low power consumption, suitable for long time working.

Specifications

Model No. ZE321
  Detection gas Alcohol
Output UART(5V TTL)
Working voltage  12VDC(9~16V DC) 
Sleeping current <0.2mA
 Maximum Operating Current <3A
range  0 ~ 2mg/l 
Inaccuracy Not more than±0.02mg/l or±10% of nominal value , whichever is greater
Working temperature  -40℃ ~ 85℃
Working humidity 15%RH~ 90%RH (no condensation)
Calibration period 6 months
lifespan  3 years
Blow flow rate More than0.3L/s less than1L/s
Blow time 3~5s

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER

RELATED PRODUCTS