Target: R290
Model: ZRT531
Detection range: 0~100%LFL
Detection principle: NDIR
Characteristics: Intelligent algorithms, electromagnetic interference resistance, high sensitivity, fast response, resistance to water vapor interference, excellent stability and long service life.
Output signal: LIN
Resolution and accuracy: Resolution 0.1%LFL; Accuracy ±2.5%LFL at 0~25%LFL and ±10% Reading at 25~100%LFL
Response time: <15s
Working Temperature: -40~85℃


Get Price Whatsapp

Description

ZRT531 is an intelligent automotive refrigerant leak sensor based on non-dispersive infrared technology. It provides good selectivity and operates independently of oxygen concentration.

The compact module integrates infrared absorption sensing, micromachining technology and signal-processing circuitry for R290 leak monitoring in automotive air-conditioning systems. 

Application

  • Automotive Air Conditioning System 

Features

  • NDIR technology
  • Excellent selectivity
  • No oxygen dependence
  • Intelligent algorithms
  • Electromagnetic interference resistance
  • High sensitivity
  • Fast response time
  • Resistance to water vapor interference
  • Excellent stability
  • Long service life
  • Compact structure
  • LIN communication

Specifications

Technical Principle NDIR
Detection Target R290
Detection Range 0~100%LFL
Resolution 0.1%LFL
Detection Accuracy ±2.5%LFL (@0%~25%LFL); ±10% Reading (@25%~100%LFL)
Operating Voltage 9~16V DC
Average Current <80mA
Peak Current <100mA
Output Mode LIN
Warm-up Time <30s
Response Time <15s
Operating Conditions -40~85℃; 0~100%RH

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com

Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.

LEADING GAS SENSING SOLUTION SUPPLIER

RELATED PRODUCTS