| Target: | Propane (C3H8) / Liquefied Gas |
| Model: | MPn-5 |
| Detection range: | 0~5250ppm |
| Detection principle: | Semiconductor |
| Characteristics: | UL 2075 certified, high sensitivity to C3H8, up to 10-year service life, excellent anti-interference ability, excellent stability and metal-cap package. |
Get Price Whatsapp
Description
The MPn-5 semiconductor propane sensor adopts a multi-layer thick-film manufacturing process. A heating electrode, measuring electrode and metal oxide semiconductor gas-sensitive layer are integrated on an Al2O3 ceramic substrate and encapsulated in a metal housing.
When propane is present in the ambient air, the conductivity of the sensing material changes with gas concentration. This conductivity change can be converted into an electrical output signal through a simple measurement circuit.
MPn-5 provides high sensitivity to C3H8, excellent stability and enhanced resistance to common interfering gases. The sensor has achieved UL 2075 certification and is designed for a service life of up to 10 years, supporting OEM manufacturers developing residential, commercial and industrial combustible gas detection products.
Application
- Propane gas leak alarms
- Liquefied gas leak monitoring devices
- Combustible gas detectors
- Residential gas leak detectors
- Commercial gas leak detectors
- Factory gas leak detection systems
- Home fire and safety detection systems
- Commercial fire and safety detection systems
- Gas leak alarms
- OEM propane detectors
- OEM combustible gas detection products
Features
- UL 2075 certified
- Up to 10-year service life
- High sensitivity to C3H8
- Excellent anti-interference ability
- Excellent long-term stability
- Enhanced resistance to common household interferents
- Reduced cross-sensitivity to alcohol
- Designed to reduce interference from cooking vapors
- Designed to reduce interference caused by humidity changes
- Multi-layer thick-film manufacturing process
- Metal oxide semiconductor sensing technology
- Compact metal-cap package
- Suitable for OEM gas detector integration
- In-house control of core materials and manufacturing processes
- Stable product quality
- Stable supply and lead-time support
Specifications
| Model | MPn-5 |
| Sensor Type | Flat Surfaced |
| Standard Encapsulation | Metal Cap |
| Target Gas | Liquefied Gas / C3H8 |
| Detection Range | 0~5250ppm |
| Loop Voltage (Vc) | ≤24V DC |
| Heater Voltage (VH) | 5V±0.1V AC or DC |
| Load Resistance (RL) | Adjustable |
| Heater Consumption (PH) | 305±25mW |
| Heater Current (IH) | 61±5mA |
| Sensitive Resistance (RS) | 1kΩ~20kΩ (in 2000ppm C3H8) |
| Sensitivity (S) | Rs(in air) / Rs(in 2000ppm C3H8) ≥8 |
| Concentration Slope (α) | ≤0.6 (R2000ppm / R500ppm C3H8) |
| Standard Test Temperature / Humidity | 20℃±2℃; 55%±5%RH |
| Standard Test Circuit | Vc: 5V±0.1V; VH: 5V±0.1V |
| Preheat Time | Not less than 48 hours |
| O2 Content | 21% (not less than 18%) |
| Lifespan | 10 Years |
| Certification | UL 2075 |
* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.
Technical Support:
Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.
The sensors don't have sleeping mode. It can be set in program if needed.
All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.
The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.
However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.
15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.
Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.
Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.
Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com
Due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. But we will reply to your inquiry in 24 business hours.