Target: CH4 methane
Model: MH-441D
Detection range: Optional within the range of 0-10% Vol
Detection principle: non-dispersive infrared (NDIR) principle
Characteristics: High sensitivity, high resolution, fast response
Size: Φ20×22.4mm
Response time: T90 < 30 s

MH-441D Manual download
Get Price Whatsapp

Description

MH-441D infrared gas sensor is a miniature universal intelligent sensor, which adopts NDIR theory to detect concentration of Carbon hydrogen combustible gas in air and has good selectivity, stable performance, long life, also is independent of Oxygen. The inside temperature sensor could be used for temperature compensation. This miniature infrared gas sensor is developed by the tight integration of mature infrared absorbing gas detection technology, micro machine workout and superior circuit design.
It is convenient in use and also instead of catalytic component directly, widely used in various occasions with combustible gas and explosion hazard gas.

Application

Widely used for HVAC refrigeration, air monitoring indoor; Industrial-process control and safety protection; Agriculture and animal husbandry.

Features

  • High sensitivity, high resolution, fast response
  • Output method: UART, analog voltage signal, etc.
  • Temperature compensation, excellent linear output, excellent stability, Long lifespan
  • Anti-poisons, anti-vapor interference
  • Anti water vapor interference, non-toxic, can directly replace catalytic combustion principle sensors
  • Can be used in high-density dust environments

Specifications

Item Parameter
Part Number MH-441D
Detection Gas Methane
Working Voltage 3.6~5V DC (Require powered by safety barrier)
Average Current <85mA(Peak current<100mA) @ 5VDC
Detection Range Optional within the range of 0-10% Vol (Table 2 for more details)
Output Signal UART-TTL (3.3V compatible with 5V)
0.4~2.0V
Warm-up time 3 min
Response time T90 < 30S
Working Temperature -20°C ~ 60°C
Working Humidity 0~95%RH (no condensation)
Sizes Φ20×22.4mm
Weight 35g
Lifetime >5 years
Defense Grade IP54
Power, communication terminal Intrinsic safety Ui=7.5VDC, Ii=265mA, Pi=0.5W, Ci=10 μF, Li=0μH

Target Gas Molecular Formula Measuring Range Resolution No. of decimal Accuracy Note
Methane CH4 0~5.00% Vol 0.01% Vol 2 Digits ±3%FS @(10℃-40℃) ±5%FS @(-40℃-10℃,40 ℃-70℃))   General Procedures
0~10.00% Vol 2 Digits
Propane C3H8 0~100% LEL 0.1%LEL 1 Digits
Acetylene C2H2 0~100% LEL 0.1%LEL 1 Digits
Isobutane C4H10 0~100% LEL 0.1%LEL 1 Digits Organic vapor detection program
Ethanol C2H5OH 0~100% LEL 1%LEL None ±5%FS @(10℃-40℃) ±10%FS @(-40℃-10℃,40 ℃-70℃))   Organic vapor detection program (when propane is used for standardization and inspection.Accuracy equivalent to propane.)

* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.

Technical Support:

Customized technical design and function, LOGO and package are available without extra charge (including molding fee) for mass volume.

The sensors don't have sleeping mode. It can be set in program if needed.

All Winsen products go through strict inspections and tests to make sure they are 100% qualified before shipping out.

The sensor has been fully tested (not calibrated) before leaving the factory, but the module will be calibrated before leaving the factory.

However, after transportation and storage, the environment conditions change, and the surface of the sensor absorbs moisture, mixed gas, pollution matters, etc. It is recommended that customers perform aging and calibration after sensors become stable according to the program and use occasions of the whole device.

15﹪-90﹪RH without condensation,greater or less than this range or long-term high temperature and high humidity will affect the life of the sensor.

Our sensors are certified with CE, 3C, ROHS, anti-explosion, fire prevention, and coal mining safety according to different applications. And we provide assistance for new certification.

Many factors can cause the sensor to fail such as broken wires in transportation, poisoning, falling off of the sensitive material, damage to the heating wire (device), etc. Please find specific cause in each category with Winsen’s aftersales.

Winsen provides professional consultation and service before and after sales. We will recommend the best fitting sensor for your demand. If you have any problem, don’t hesitate to email us to sales@winsensor.com