![US1010 Ultrasonic Oxygen Sensor](/d/pic/newpic/us1010.jpg)
US1010 Ultrasonic Oxygen Sensor
- O2
- 20.5%~95.6%
- Read More
![MH-Z9041A TDLAS Laser Methane Sensor](/d/pic/newpic/mh-z9041a.jpg)
MH-Z9041A TDLAS Laser Methane Sensor
- Methane CH4
- 3-100%LEL (can be customized)
- Read More
![MEs-CO Carbon Monoxide sensor](/d/pic/newpic/mes-co.jpg)
MEs-CO Carbon Monoxide sensor
- CO Carbon Monoxide Gas
- 0~1000ppm
- Read More
![Residential Ultrasonic Gas Flow Meter](/d/pic/newpic/ultrasonic-domestic-gas-meter.jpg)
Residential Ultrasonic Gas Flow Meter
- CH4 methane, Natural Gas, LPG Gas and other combustible gas
- Read More
![ZS13 Temperature and Humidity Sensor Module](/d/pic/newpic/zs13.jpg)
ZS13 Temperature and Humidity Sensor Module
- Temperature and Humidity
- Read More
![ZRP320 Pyro-electric Flame sensor module](/d/pic/newpic/zrp320.jpg)
ZRP320 Pyro-electric Flame sensor module
- Hydrocarbon combustion
- Read More
![MP511D Refrigerant Gas Sensor](/d/pic/newpic/mp511d.jpg)
MP511D Refrigerant Gas Sensor
- Refrigerant gas
- 200~10000ppm
- Read More
![MH-T4041A Low Power Consumption Infrared Gas Sensor](/d/pic/newpic/mh-t4041a.jpg)
MH-T4041A Low Power Consumption Infrared Gas Sensor
- Hydrocarbon flammable gases
- 0~10% Vol optional(refer to sheet 2)
- Read More
![ZP16-A Air-Quality Detection Module](/d/pic/newpic/zp16-a.jpg)
ZP16-A Air-Quality Detection Module
- Formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, smoke of cigarette, essence &etc
- VOC:0-2.000mg/m3 CO2:350-2000ppm CH2O:0-1.000mg/m3
- Read More
![MC21B Catalytic Flammable Gas Sensor](/d/pic/newpic/mc21b.jpg)
MC21B Catalytic Flammable Gas Sensor
- Combustible gas
- 0~100
- Read More
![Digital ZM106-VOC Module](/d/pic/newpic/zm106.jpg)
Digital ZM106-VOC Module
- VOC, Ethanol, formaldehyde, toluene and other organic volatiles
- 0~10mg/m3
- Read More
![ZEH100 Multi-in-One Energy Storage Sensor Module](/d/pic/newpic/zed100.jpg)
ZEH100 Multi-in-One Energy Storage Sensor Module
- CO, H2, VOC, Smoke, Temperature
- Read More
![MH-L1141A-U-100L Laser Sensor](/d/pic/newpic/mh-l1141a-u.jpg)
MH-L1141A-U-100L Laser Sensor
- Methane(CH4)
- 0~100%LEL
- Read More
![MC33J Catalytic Gas Sensor](/d/pic/newpic/mc33j.jpg)
MC33J Catalytic Gas Sensor
- H2
- 0~100
- Read More
![MP810 Hydrogen Gas Sensor](/d/pic/newpic/mp-810.jpg)
MP810 Hydrogen Gas Sensor
- H2
- 100~3000ppm
- Read More
![MH-T7042A Infrared CH4 Gas Sensor](/d/pic/newpic/mh-t7042a.jpg)
MH-T7042A Infrared CH4 Gas Sensor
- Combustible gas(CH4)
- 0~100%VOL optional
- Read More
![ZE610-H2 Electrochemical H2 Module](/d/pic/newpic/ze610-h2.jpg)
ZE610-H2 Electrochemical H2 Module
- Hydrogen gas (H2)
- 0~5000ppm
- Read More
![MPv-820 Hydrogen Gas Sensor](/d/pic/newpic/mpv-820.jpg)
MPv-820 Hydrogen Gas Sensor
- H2
- 100~3000ppm
- Read More
![MEv-GH01 Hydrogen Gas Sensor](/d/pic/newpic/mev-gh01.jpg)
MEv-GH01 Hydrogen Gas Sensor
- H2
- 0~2000ppm
- Read More
![ZE809-OU Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE809-OU Malodorous Gases Odor Sensor Module
- Stench, odor
- 0~100 OU
- Read More
![ZE808-C8H8 Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE808-C8H8 Malodorous Gases Odor Sensor Module
- Styrene(C8H8)
- 0 ~ 10 PPM
- Read More
![ZE807-CS2 Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE807-CS2 Malodorous Gases Odor Sensor Module
- CS2
- 0 ~ 10 PPM
- Read More
![ZE806-C2H6S2 Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE806-C2H6S2 Malodorous Gases Odor Sensor Module
- C2H6S2
- 0 ~ 10 PPM
- Read More
![ZE805-C2H6S Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE805-C2H6S Malodorous Gases Odor Sensor Module
- dimethyl sulfide, C2H6S
- 0-10ppm
- Read More
![ZE804-CH4S Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE804-CH4S Malodorous Gases Odor Sensor Module
- Methyl Mercaptan, CH4S
- 0~10 PPM
- Read More
![ZE803-H2S Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE803-H2S Malodorous Gases Odor Sensor Module
- H2S
- 0 ~ 10 PPM
- Read More
![ZE802-C3H9N Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE802-C3H9N Malodorous Gases Odor Sensor Module
- C3H9N
- 0 ~ 10 PPM
- Read More
![ZE801-NH3 Malodorous Gases Odor Sensor Module](/d/pic/newpic/ze809.jpg)
ZE801-NH3 Malodorous Gases Odor Sensor Module
- NH3
- 0 ~ 50 PPM
- Read More
![MPn-4C CH4 Methane Flammable Gas Sensor](/d/pic/newpic/mpn-4c.jpg)
MPn-4C CH4 Methane Flammable Gas Sensor
- CH4, Methane, Natural gas, marsh gas
- 300~10000ppm (methane, natural gas)
- Read More
![Anti-intrusion Sensor](/d/pic/newpic/anti-intrusion-senso.jpg)
Anti-intrusion Sensor
- Life form
- Detection distance:3m
Temperature:-55~125℃ - Read More
![ZHMT101- Life Presence Sensor](/d/pic/newpic/zhmt101.jpg)
ZHMT101- Life Presence Sensor
- Life form
- Detection field of view range:0.6*1.4*0.6m
CO2:400~5000ppm
Temperature:-55~125℃ - Read More
![ZH401- Light Sensor](/d/pic/newpic/zh401.jpg)
ZH401- Light Sensor
- Light
- 1500~6000lx
- Read More
![ZH101- Light and Rainfall Composite Sensor](/d/pic/newpic/zh101.jpg)
ZH101- Light and Rainfall Composite Sensor
- Water & Light
- Rainfall:7*7mm(Rainfall detection area)
Lighting directly above:1000~50000lx(Light intensity detection range)
Front light:1000~100000lx(Light intensity detection range)
Temperature:-40~85℃
Humidity:0~100%RH - Read More
![Alcohol Detection Sensor](/d/pic/newpic/alcohol.jpg)
Alcohol Detection Sensor
- Alcohol
- 0~440mg/100ml(0~2mg/L)
- Read More
![ZW-HC101- On-line Conductivity Sensor](/d/pic/newpic/zw-hc101.jpg)
ZW-HC101- On-line Conductivity Sensor
- Coolant
- 0.01~20 uS/cm
- Read More
![ZPH07- Lithium Battery Aerosol Monitoring Sensor](/d/pic/newpic/zph07.jpg)
ZPH07- Lithium Battery Aerosol Monitoring Sensor
- Aerosol
- 0~10000μg/m³
- Read More
![ZEQH-101- All-in-one Lithium Battery Thermal Runaway Sensor](/d/pic/newpic/zeqh-101.jpg)
ZEQH-101- All-in-one Lithium Battery Thermal Runaway Sensor
- CO, CO2, VOC, temperature, pressure
- CO:0~1000ppm
CO2:400~10000ppm
VOC:200~10000ppm
Pressure:0 ~130kPa
Temperature:-40℃~200℃ - Read More
![ZC401- Natural Gas Leak Sensor (CH4)](/d/pic/newpic/zc41.jpg)
ZC401- Natural Gas Leak Sensor (CH4)
- Natural gas, liquefied gas, coal gas, alkanes and other flammable gases
- 0~100%LEL
- Read More
![ZMHS10- All-in-one Air Quality Sensor](/d/pic/newpic/zmhs10.jpg)
ZMHS10- All-in-one Air Quality Sensor
- PM2.5, CO2, AQS, Temperature and humidity
- PM2.5:0~1000μg/m³
CO2:400~10000ppm
AQS:CO: 1~5000ppm, NOx: 0~10ppm, NH3: 1~300ppm
Temperature:-40~125℃
Humidity:0~100%RH - Read More
![ZRP330 Pyro-electric Flame sensor module](/d/pic/newpic/zrp330.jpg)
ZRP330 Pyro-electric Flame sensor module
- Hydrocarbon combustion
- Read More
![MR007 CH4 Methane C3H8 Propane Gas Sensor](/d/pic/newpic/mr007.jpg)
MR007 CH4 Methane C3H8 Propane Gas Sensor
- CH4 methane C3H8 propane, combustible gas, natural gas, coal gas, LPG gas
- 0~100 LEL
- Read More
![MEu-CO Carbon Monoxide Sensor](/d/pic/newpic/meu-co.jpg)
MEu-CO Carbon Monoxide Sensor
- Carbon monoxide(CO)
- 0~1000ppm
- Read More
![Electrochemical Carbon Monoxide Gas Sensor Module ZE730-CO](/d/pic/newpic/ze730-co.jpg)
Electrochemical Carbon Monoxide Gas Sensor Module ZE730-CO
- Carbon Monoxide Gas
- 0~1000ppm
- Read More
![Electrochemical HCHO Formaldehyde Sensor Module ZE08B-CH2O](/d/pic/newpic/ze08b-ch2o.jpg)
Electrochemical HCHO Formaldehyde Sensor Module ZE08B-CH2O
- CH2O, HCHO, Formaldehyde
- 0~1.6ppm
- Read More
![Air-Quality Detection Module ZE40-TVOC](/d/pic/newpic/ze40-tvoc.jpg)
Air-Quality Detection Module ZE40-TVOC
- TVOC
- 0~5 ppm
- Read More
![Electrochemical HCHO Formaldehyde Sensor ZE08K-CH2O](/d/pic/newpic/ze08k-ch2o.jpg)
Electrochemical HCHO Formaldehyde Sensor ZE08K-CH2O
- CH2O, HCHO, Formaldehyde
- 0~5ppm
- Read More
![ME3-CS2 Electrochemical Gas Sensor](/d/pic/newpic/me3-cs2.jpg)
ME3-CS2 Electrochemical Gas Sensor
- CS2
- 0~100ppm
- Read More
![ME3-C3H9N Electrochemical Gas Sensor](/d/pic/newpic/me3-c3h9n.jpg)
ME3-C3H9N Electrochemical Gas Sensor
- C3H9N
- 0~100ppm
- Read More
![ME3-C2H6S2 Electrochemical Gas Sensor](/d/pic/newpic/me3-c2h6s2.jpg)
ME3-C2H6S2 Electrochemical Gas Sensor
- C2H6S2
- 0~100ppm
- Read More
![ME3-C2H6S Electrochemical Gas Sensor](/d/pic/newpic/me3-c2h6s.jpg)
ME3-C2H6S Electrochemical Gas Sensor
- C2H6S
- 0~100ppm
- Read More
![ME3-CH4S Electrochemical Gas sensor](/d/pic/newpic/me3-ch4s.jpg)
ME3-CH4S Electrochemical Gas sensor
- CH4S
- 0~100ppm
- Read More
![ME3-C8H8 Electrochemical Gas Sensor](/d/pic/newpic/me3-c8h8.jpg)
ME3-C8H8 Electrochemical Gas Sensor
- C8H8
- 0~100ppm
- Read More
![ME3-C2H3Cl Electrochemical Gas Sensor](/d/pic/newpic/me3-c2h3cl.jpg)
ME3-C2H3Cl Electrochemical Gas Sensor
- C2H3Cl (chloroethylene)
- 0~20ppm
- Read More
![ZC61 vehicle hydrogen leakage detection sensor](/d/pic/newpic/zc61.jpg)
ZC61 vehicle hydrogen leakage detection sensor
- Hydrogen (H2)
- 0-40000ppm
- Read More
![ZPS20 Digital Sensor Module - VOC Temperature Humidity](/d/pic/newpic/zps20.jpg)
ZPS20 Digital Sensor Module - VOC Temperature Humidity
- Formaldehyde, benzene, VOC, Temperature, Relative humidity
- 0~10mg/m3
- Read More
![ZPH05 Micro-dust Sensor](/d/pic/newpic/zph05.jpg)
ZPH05 Micro-dust Sensor
- Micro-dust
- Read More
![GMV-2021B MEMS H2 Sensor](/d/pic/newpic/mems.jpg)
GMV-2021B MEMS H2 Sensor
- hydrogen H2 gas leakage
- 0.1~1000ppm(H2)
- Read More
![ZRT510 Refrigerant Sensor Module](/d/pic/newpic/zrt510.jpg)
ZRT510 Refrigerant Sensor Module
- R454B, R32, R290, Refrigerant
- Read More
![ZP16 Air-Quality Detection Module](/d/pic/newpic/zp16.jpg)
ZP16 Air-Quality Detection Module
- Formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, smoke of cigarette, essence &etc.
- 0-10mg/m3
- Read More
![ZP211 Refrigerant gas detection module](/d/pic/newpic/zp211.jpg)
ZP211 Refrigerant gas detection module
- Refrigerant gas R290
- Read More
![ZH10-VHT Compact 4-in-1 Air Quality Sensor Module](/d/pic/newpic/zh10-f.jpg)
ZH10-VHT Compact 4-in-1 Air Quality Sensor Module
- PM2.5,VOC,Temperature,Humidity
- Read More
![ZH10-F Compact Laser Dust Sensor Module](/d/pic/newpic/zh10-f.jpg)
ZH10-F Compact Laser Dust Sensor Module
- PM1.0,PM2.5,PM10
- 0-1000 μg/m³
- Read More
![ZH09 Laser dust sensor](/d/pic/newpic/zh09.jpg)
ZH09 Laser dust sensor
- PM1.0,PM2.5,PM10
- 0-100 μg/m³:±15μg/m³ 101-1000 μg /m³: ± 15% Reading (Test Condition: 25 ± 2 ℃, 50 ± 10%RH, Grimm, Cigarette, GBT18801-2015
- Read More
![ZP101 Burnt Smell Detection Module](/d/pic/newpic/zp101.jpg)
ZP101 Burnt Smell Detection Module
- Food burnt gas
- 820~1300(10ppm alcohol) (20℃-26℃/30%RH~70%RH)
- Read More
![Electrochemical HCHO Formaldehyde Sensor ZE510-CH2O](/d/pic/newpic/ze510-ch2o.jpg)
Electrochemical HCHO Formaldehyde Sensor ZE510-CH2O
- CH2O, HCHO, Formaldehyde
- 0~5ppm
- Read More
![MEu-H2S Hydrogen Sulfide Gas Sensor](/d/pic/newpic/meu-h2s.jpg)
MEu-H2S Hydrogen Sulfide Gas Sensor
- Hydrogen Sulfide(H2S)
- 0~100ppm
- Read More
![UE-NH3 Electrochemical Gas Sensor](/d/pic/newpic/ue-nh3.jpg)
UE-NH3 Electrochemical Gas Sensor
- Ammonia NH3
- 0~100ppm
- Read More
![ZS21 Temperature and Humidity Sensor Module](/d/pic/newpic/zs21.jpg)
ZS21 Temperature and Humidity Sensor Module
- Temperature and Relative Humidity
- Read More
![CMV-2021D Catalytic H2 Hydrogen Gas Sensor](/d/pic/newpic/cmv-2021d.jpg)
CMV-2021D Catalytic H2 Hydrogen Gas Sensor
- hydrogen H2 gas
- 0~100 %LEL
- Read More
![WHT30 MEMS type Temperature and Humidity Sensor](/d/pic/newpic/wht30.jpg)
WHT30 MEMS type Temperature and Humidity Sensor
- Environment relative humidity,temperature
- Read More
![ZH10 Compact 4-in-1 Air Quality Sensor Module](/d/pic/newpic/zh10-f.jpg)
ZH10 Compact 4-in-1 Air Quality Sensor Module
- PM2.5,VOC,Temperature,Humidity
- Read More
![MEu-2CO Carbon Monoxide Sensor Over 7 years lifetime](/d/pic/newpic/meu-2co.jpg)
MEu-2CO Carbon Monoxide Sensor Over 7 years lifetime
- Carbon monoxide(CO)
- 0~500ppm,Max Range 1000ppm
- Read More
![MH-Z1542B-R32 Refrigerant Sensor Module](/d/pic/newpic/mh-z1542b-r32.jpg)
MH-Z1542B-R32 Refrigerant Sensor Module
- Refrigerant
- 0~5.00% Vol
- Read More
![MH-441D NDIR Infrared Refrigerant Sensor](/d/pic/newpic/mh-441d-refrigerant.jpg)
MH-441D NDIR Infrared Refrigerant Sensor
- Refrigerant,R32,R454B,R410A,R134A
- 0~5%VOL
- Read More
![ME2-CO-Φ14x5 Carbon Monoxide Gas Sensor](/d/pic/newpic/me2-co-%CE%A614x5.jpg)
ME2-CO-Φ14x5 Carbon Monoxide Gas Sensor
- CO
- 0~1000ppm
- Read More
![ZH30/ZH32- Single/Dual Channel Laser Dust Sensor (PM2.5)](/d/pic/newpic/zh30.jpg)
ZH30/ZH32- Single/Dual Channel Laser Dust Sensor (PM2.5)
- PM1.0,PM2.5,PM10
- 0-1000μg/m³
- Read More
![ZM102 AQS Air Quality Sensor for Automotive](/d/pic/newpic/zm102.jpg)
ZM102 AQS Air Quality Sensor for Automotive
- CO/HC、NOx、NH3
- Read More
![MEu-2O2 Oxygen Sensor](/d/pic/newpic/meu-2o2.jpg)
MEu-2O2 Oxygen Sensor
- O2
- 0~25% VOL
- Read More
![Multi-in-One Sensor Module ZPHS01C](/d/pic/newpic/zphs01c-voc.jpg)
Multi-in-One Sensor Module ZPHS01C
- PM2.5, CO2, CH2O, TVOC,Temperature&Humidity
- CO2: 400~5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%)
- Read More
![MH-441D-454B NDIR Infrared Refrigerant Sensor](/d/pic/newpic/mh-441d-454b.jpg)
MH-441D-454B NDIR Infrared Refrigerant Sensor
- Refrigerant,R454B
- 0~5%VOL
- Read More
![MEu-O2 Oxygeon Sensor](/d/pic/newpic/meu-o2.jpg)
MEu-O2 Oxygeon Sensor
- Oxygen(O2)
- 0~25% VOL
- Read More
![US1000 Ultrasonic Oxygen Sensor](/d/pic/newpic/us1000.jpg)
US1000 Ultrasonic Oxygen Sensor
- oxygen concentration and flow in oxygen
- (Concentration)21%~95.6%/(Flow)0~10L/min
- Read More
![RDA226 Digital Pyroelectric Infrared Sensor](/d/pic/newpic/rda226.jpg)
RDA226 Digital Pyroelectric Infrared Sensor
- human body induction
- Read More
![ZQ02-O3 Ozone Module](/d/pic/newpic/zq02.jpg)
ZQ02-O3 Ozone Module
- Ozone
- 10-1000PPB
- Read More
![ME2-O2-Ф20 Oxygen Sensor](/d/pic/newpic/me2-o2.jpg)
ME2-O2-Ф20 Oxygen Sensor
- O2
- 0~25%Vol
- Read More
![ME3-CH2O Electrochemical HCHO Formaldehyde Sensor](/d/pic/newpic/me3-ch2o.jpg)
ME3-CH2O Electrochemical HCHO Formaldehyde Sensor
- CH2O, HCHO, Formaldehyde
- 0~10ppm
- Read More
![Electrochemical HCHO Formaldehyde Sensor Module ZE07-CH2O](/d/pic/newpic/ze07-ch2o.jpg)
Electrochemical HCHO Formaldehyde Sensor Module ZE07-CH2O
- CH2O, HCHO, Formaldehyde
- 0~5ppm
- Read More
![MP135 Air-Quality Gas Sensor](/d/pic/newpic/mp.jpg)
MP135 Air-Quality Gas Sensor
- H2,Alcohol, CO
- H2:10~500ppm
Alcohol:5~500ppm
CO:10~500ppm - Read More
![WSP2110 VOC Gas Sensor](/d/pic/newpic/mp.jpg)
WSP2110 VOC Gas Sensor
- toluene, methanal, benzene, alcohol, acetone &etc.
- 1~50ppm
- Read More
![WSP5110 Refrigerant Gas Sensor](/d/pic/newpic/wsp5110.jpg)
WSP5110 Refrigerant Gas Sensor
- Refrigerant, benzene, alcohol &etc.
- 10~1000ppm
- Read More
![Photoionization PID Sensor 4R-PID](/d/pic/newpic/4r-pid.jpg)
Photoionization PID Sensor 4R-PID
- VOC,Energy≤10.6eV Volatile Gases
- 0~10000 ppm
- Read More
![Electrochemical TVOC Detection Module ZE40B-TVOC](/d/pic/newpic/ze40b.jpg)
Electrochemical TVOC Detection Module ZE40B-TVOC
- Alcohol
- 0~2 ppm
- Read More
![ME3-HCL gas sensor](/d/pic/newpic/me3-hcl.jpg)
ME3-HCL gas sensor
- HCL
- 0~20ppm
- Read More
![ZPH01 Air-quality and Particles Sensor](/d/pic/newpic/zph01.jpg)
ZPH01 Air-quality and Particles Sensor
- PM2.5
- 15000 particles /283ml
- Read More
![MH-741A Infrared CH4 Methane Gas Sensor](/d/pic/newpic/mh-741a.jpg)
MH-741A Infrared CH4 Methane Gas Sensor
- CH4 methane, natural gas, combustible gas
- 0~100%VOL optional
- Read More
![ZC01 Methane CH4 Sensor Module for Mine Use](/d/pic/newpic/zc01.jpg)
ZC01 Methane CH4 Sensor Module for Mine Use
- CH4 methane gas
- Read More
![ZC02 CH4 Methane Gas Sensor Module for Mine Use](/d/pic/newpic/zco2.jpg)
ZC02 CH4 Methane Gas Sensor Module for Mine Use
- CH4 methane gas
- Read More
![ZP05 Vehicle-Mounted Fuel Gas Leakage Detection Module](/d/pic/newpic/zp05.jpg)
ZP05 Vehicle-Mounted Fuel Gas Leakage Detection Module
- Natural gas
- 1~25%LEL
- Read More
![ZP10 Vehicle-Mounted Fuel Gas Leakage Detection Module](/d/pic/newpic/zp10.jpg)
ZP10 Vehicle-Mounted Fuel Gas Leakage Detection Module
- Natural gas, LPG, Manufactured Gas
- 1~25%LEL
- Read More
![MR513 Hot-wire Alcohol Gas sensor](/d/pic/newpic/mr513.jpg)
MR513 Hot-wire Alcohol Gas sensor
- C2H5OH, alcohol, ethanol
- Read More
![MD61 Gas Sensor Detection of Methane Hydrogen Inert gases](/d/pic/newpic/md61.jpg)
MD61 Gas Sensor Detection of Methane Hydrogen Inert gases
- Methane, hydrogen, inert gases
- 0~100%
- Read More
![MG-812 Low Power-Consumption CO2 Sensor](/d/pic/newpic/mg-812.jpg)
MG-812 Low Power-Consumption CO2 Sensor
- CO2
- 0~ 10000ppm CO2
- Read More
![Multi-in-One ZPHS01B Sensor Module](/d/pic/newpic/zphs01b.jpg)
Multi-in-One ZPHS01B Sensor Module
- CO2. PM2.5. CH2O. O3. CO. TVOC. NO2. Temperature. Humidity
- See Manul
- Read More
![MW-TDS101 TDS Water Quality Sensor](/d/pic/newpic/mw-tds101.jpg)
MW-TDS101 TDS Water Quality Sensor
- TDS
- 0-2000ppm
- Read More
![ZW-TDS102 TDS Water Quality Detection Module](/d/pic/newpic/zw-tds102.jpg)
ZW-TDS102 TDS Water Quality Detection Module
- TDS
- 0-2000μs/cm
- Read More
![ZE29A-C2H5OH Electrochemical Alcohol Module](/d/pic/newpic/ze29a-c2h5oh.jpg)
ZE29A-C2H5OH Electrochemical Alcohol Module
- Alcohol
- 0~1.0 mg/l
- Read More
![Gas Flow Sensor FR20](/d/pic/newpic/fr20.jpg)
Gas Flow Sensor FR20
- Measure the mass flow of gases in the pipe, dry and non-corrosive gases
- 150/200/300
- Read More
![Flow Sensor FR06](/d/pic/newpic/fr06.jpg)
Flow Sensor FR06
- Flow monitoring of pipeline gas medium
- 150/200/300
- Read More
![Gas Flow Sensor FR03](/d/pic/newpic/fr03.jpg)
Gas Flow Sensor FR03
- Mass gas flow monitoring of gas medium in the pipe
- 0.2/0.3/0.4/0.5SLM
- Read More
![Gas Flow Sensor FR03H](/d/pic/newpic/fr03h.jpg)
Gas Flow Sensor FR03H
- Mass gas flow monitoring of gases in the pipe
- 5L/min @20℃ 101.325kPa
- Read More
![F1032 Flow Sensor](/d/pic/newpic/f1032.jpg)
F1032 Flow Sensor
- Flow monitoring of pipeline gas medium
- 20、35、50、100、150、 200 SLM
- Read More
![F1031V Micro Gas Flow Sensor](/d/pic/newpic/f1031v-2.jpg)
F1031V Micro Gas Flow Sensor
- Mass gas flow measurement in the flow channel
- 100, 150, 200, 300SLM
- Read More
![F1031 Micro Gas Flow Sensor](/d/pic/newpic/f1031.jpg)
F1031 Micro Gas Flow Sensor
- Mass gas flow measurement in the flow channel
- Read More
![F1022 Micro Flow Sensor](/d/pic/newpic/f1022.jpg)
F1022 Micro Flow Sensor
- Flow detection of the gas medium in the flow channel
- 5、10、15、20 SLM
- Read More
![F1013 Micro Gas Flow Sensor](/d/pic/newpic/f1013.jpg)
F1013 Micro Gas Flow Sensor
- Gas mass measurement and control in the flow channel
- 50、100、200、500、1000、2000sccm
- Read More
![F1012 Micro Gas Flow Sensor](/d/pic/newpic/f1012.jpg)
F1012 Micro Gas Flow Sensor
- Mass gas measurement and control in the flow channel
- 50、100、200、500、1000、2000sccm
- Read More
![ZH08 Laser dust sensor](/d/pic/newpic/zh08.jpg)
ZH08 Laser dust sensor
- PM1.0,PM2.5,PM10
- Read More
![ZH07 Laser dust sensor](/d/pic/newpic/zh07.jpg)
ZH07 Laser dust sensor
- particulate matters PM1.0, PM2.5, PM10
- 0-1000μg/m³
- Read More
![ZH06-IV Laser dust sensor](/d/pic/newpic/zh06-%E2%85%A3.jpg)
ZH06-IV Laser dust sensor
- PM1.0,PM2.5,PM10
- 0-1000μg/m³
- Read More
![ZH06-III Laser dust sensor](/d/pic/newpic/zh06-%E2%85%A2.jpg)
ZH06-III Laser dust sensor
- PM1.0,PM2.5,PM10
- 0-1000μg/m³
- Read More
![ZH06-II Laser dust sensor](/d/pic/newpic/zh06-%E2%85%A1.jpg)
ZH06-II Laser dust sensor
- PM1.0,PM2.5,PM10
- 0-1000μg/m³
- Read More
![ZH06-Ⅰ Laser dust sensor](/d/pic/newpic/zh06-%E2%85%A0.jpg)
ZH06-Ⅰ Laser dust sensor
- PM1.0,PM2.5,PM10
- 0-1000μg/m³
- Read More
![ZH03B Laser Dust Sensor Module](/d/pic/newpic/zh03b.jpg)
ZH03B Laser Dust Sensor Module
- PM1.0,PM2.5,PM10
- 0-1000μg/m³
- Read More
![ZPH04B Particles Sensor](/d/pic/newpic/zph04.jpg)
ZPH04B Particles Sensor
- PM2.5
- 0-500ug/m3
- Read More
![ZPH03 Particles Sensor](/d/pic/newpic/zph03.jpg)
ZPH03 Particles Sensor
- PM2.5
- 4 ~ 500ug/m³
- Read More
![MQ-7B Semiconductor Sensor for Carbon Monoxide](/d/pic/newpic/mq-3b.jpg)
MQ-7B Semiconductor Sensor for Carbon Monoxide
- CO
- 10-500ppm
- Read More
![MQ316 Mouth smell sensor](/d/pic/newpic/mp.jpg)
MQ316 Mouth smell sensor
- Mouth odor:C2H5OH、H2S、CH3SH
- C2H5OH(5-200ppm)
- Read More
![MQ303B Semiconductor Sensor for Alcohol Gas](/d/pic/newpic/mq303b.jpg)
MQ303B Semiconductor Sensor for Alcohol Gas
- C2H5OH
- 20-500ppm
- Read More
![MQ138 VOC Gas Sensor](/d/pic/newpic/mq.jpg)
MQ138 VOC Gas Sensor
- C7H8、CH3COCH3、C2H5OH、H2
- 5~500ppm
- Read More
![MQ137 Ammonia Gas Sensor](/d/pic/newpic/mq.jpg)
MQ137 Ammonia Gas Sensor
- NH3
- 5-500ppm
- Read More
![MQ136 Gas Sensor for Hydrogen Sulfide](/d/pic/newpic/mq.jpg)
MQ136 Gas Sensor for Hydrogen Sulfide
- H2S
- 1-200ppm
- Read More
![MQ135 Semiconductor Sensor for Air Quality](/d/pic/newpic/mq.jpg)
MQ135 Semiconductor Sensor for Air Quality
- Air pollution:NH3、sulfide、benzene series steam
- NH3、C7H8、H2、Smoke(10~1000ppm)
- Read More
![MQ131 Ozone Gas Sensor (Low Concentration)](/d/pic/newpic/mq131.jpg)
MQ131 Ozone Gas Sensor (Low Concentration)
- O3
- 10-1000ppb
- Read More
![MQ131 Ozone Gas Sensor (High Concentration)](/d/pic/newpic/mq.jpg)
MQ131 Ozone Gas Sensor (High Concentration)
- O3
- 10-1000ppm
- Read More
![MQ-9B MOS Sensor for Carbon Monoxide CO Gas](/d/pic/newpic/mq-3b.jpg)
MQ-9B MOS Sensor for Carbon Monoxide CO Gas
- CO,CH4
- CO(10-500ppm),CH4(300-10000ppm)
- Read More
![MQ-8 Hydrogen H2 Gas Sensor](/d/pic/newpic/mq.jpg)
MQ-8 Hydrogen H2 Gas Sensor
- H2 hydrogen gas
- 100-1000ppm
- Read More
![MQ-6 MOS Flammable Gas Sensor for Methane CH4 LPG Detection](/d/pic/newpic/mq.jpg)
MQ-6 MOS Flammable Gas Sensor for Methane CH4 LPG Detection
- LPG,CH4
- CH4、C3H8(300-10000ppm)
- Read More
![MQ-5B MOS Combustible Gas Sensor Detect Propane LPG Methane](/d/pic/newpic/mq-2b.jpg)
MQ-5B MOS Combustible Gas Sensor Detect Propane LPG Methane
- Propane C3H8, LPG gas, methane CH4
- CH4、C3H8(300-10000ppm)
- Read More
![MQ-5 Semiconductor Sensor for Flammable Gas](/d/pic/newpic/mq.jpg)
MQ-5 Semiconductor Sensor for Flammable Gas
- Propane C3H8, LPG gas, methane CH4
- CH4、C3H8(300-10000ppm)
- Read More
![MQ-4B MOS Flammable Gas Sensor for Methane CH4](/d/pic/newpic/mq-2b.jpg)
MQ-4B MOS Flammable Gas Sensor for Methane CH4
- methane CH4, natural gas, flammable gas
- 300-10000ppm
- Read More
![MQ-4 MOS Flammable Gas Sensor for Methane CH4 Detector](/d/pic/newpic/mq.jpg)
MQ-4 MOS Flammable Gas Sensor for Methane CH4 Detector
- methane CH4, natural gas, flammable gas
- CH4(300-10000ppm)
- Read More
![MQ-3B Semiconductor Sensor for Alcohol Gas](/d/pic/newpic/mq-3b.jpg)
MQ-3B Semiconductor Sensor for Alcohol Gas
- C2H5OH
- 25-500ppm
- Read More
![MS-Z3 Macromolecule Humidity Sensor](/d/pic/newpic/ms-z3.jpg)
MS-Z3 Macromolecule Humidity Sensor
- Environment relative humidity,temperature
- Read More
![ZS11 Temperature and Humidity Sensor Module](/d/pic/newpic/zs11.jpg)
ZS11 Temperature and Humidity Sensor Module
- Environment relative humidity,temperature
- Read More
![ZS05 Temperature and Humidity Module](/d/pic/newpic/zs05.jpg)
ZS05 Temperature and Humidity Module
- Environment relative humidity,temperature
- Read More
![ZS03 Temperature and Humidity Module](/d/pic/newpic/zs03.jpg)
ZS03 Temperature and Humidity Module
- Environment relative humidity,temperature
- Read More
![WHT20 MEMS type Temperature and Humidity Sensor](/d/pic/newpic/wht20.jpg)
WHT20 MEMS type Temperature and Humidity Sensor
- Environment relative humidity,temperature
- Read More
![MRTD-3011 Digital Thermopile Temperature Sensor](/d/pic/newpic/mrtd-3011.jpg)
MRTD-3011 Digital Thermopile Temperature Sensor
- temperature
- -20-250℃
- Read More
![RTTA71 Thermopile Temperature Sensor](/d/pic/newpic/rtta71.jpg)
RTTA71 Thermopile Temperature Sensor
- temperature
- -30-125℃
- Read More
![MRT511 Thermopile Temperature Sensor](/d/pic/newpic/mrt511.jpg)
MRT511 Thermopile Temperature Sensor
- temperature
- -30-100℃
- Read More
![MRT311S Thermopile Temperature Sensor](/d/pic/newpic/mrt311s.jpg)
MRT311S Thermopile Temperature Sensor
- temperature
- -30-100℃
- Read More
![MRT311 Thermopile Temperature Sensor](/d/pic/newpic/mrt311.jpg)
MRT311 Thermopile Temperature Sensor
- temperature
- -30-100℃
- Read More
![MW-RCl101 residual chlorine water quality sensor](/d/pic/newpic/mw-rcl101.jpg)
MW-RCl101 residual chlorine water quality sensor
- Solution
- 0~20 mg/L
- Read More
![MW-O101 dissolved oxygen water quality detection sensor](/d/pic/newpic/mw-o101.jpg)
MW-O101 dissolved oxygen water quality detection sensor
- Solution
- 0~20 mg/L
- Read More
![MW-O201 dissolved oxygen water quality detection sensor](/d/pic/newpic/mw-o201.jpg)
MW-O201 dissolved oxygen water quality detection sensor
- Liquid
- 0~20 mg/L
- Read More
![ZW-NH101 Ammonia& Nitrogen Detection Module](/d/pic/newpic/zw-nh101.jpg)
ZW-NH101 Ammonia& Nitrogen Detection Module
- Liquid
- 0~1000 mg/L
- Read More
![MW-pH101 water quality detection sensor](/d/pic/newpic/mw-ph101.jpg)
MW-pH101 water quality detection sensor
- Liquid
- 1~14
- Read More
![MW-ORP101 water quality detection sensor](/d/pic/newpic/mw-orp101.jpg)
MW-ORP101 water quality detection sensor
- Liquid
- -2000 mV ~﹢2000 mV
- Read More
![4-in-1 Industrial Gas Detection Module ZCE04B](/d/pic/newpic/zce04b.jpg)
4-in-1 Industrial Gas Detection Module ZCE04B
- CH4(1%LEL), CO(1ppm), H2S(1ppm), O2(0.1%LEL)
- 0-100%LEL ,0-1000ppm ,0-100ppm ,0-30%LEL
- Read More
![ZC13 Methane CH4 Sensor Module for Home Gas Safety](/d/pic/newpic/zc13.jpg)
ZC13 Methane CH4 Sensor Module for Home Gas Safety
- methane CH4, natural gas, flammable gas
- 1%-25%LEL,Resolution100ppm
- Read More
![ZC08-CH4 Methane Sensor Module for Home Natural Gas Leakage](/d/pic/newpic/zc08.jpg)
ZC08-CH4 Methane Sensor Module for Home Natural Gas Leakage
- methane CH4, natural gas, flammable gas
- 1%-20%LEL,Resolution100ppm
- Read More
![ZC08-H2 Hydrogen Sensor Module for Home Gas Alarm](/d/pic/newpic/zc08-h2.jpg)
ZC08-H2 Hydrogen Sensor Module for Home Gas Alarm
- H2 hydrogen
- 0-20000ppm,Resolution100ppm
- Read More
![ZC05 Methane CH4 Gas Sensor Module for Home Use](/d/pic/newpic/zc05-mc105.jpg)
ZC05 Methane CH4 Gas Sensor Module for Home Use
- Natural gas, methane CH4 gas
- 1%-25%LEL,Resolution100ppm
- Read More
![Atmospheric Monitoring Sensor Module ZEHS04](/d/pic/newpic/zehs04.jpg)
Atmospheric Monitoring Sensor Module ZEHS04
- CO, SO2, NO2, O3 (Scalable PM2.5, PM10, Temperature, Humidity)
- See manual
- Read More
![Electrochemical Alcohol Module ZE31-C2H5OH](/d/pic/newpic/ze31-c2h5oh.jpg)
Electrochemical Alcohol Module ZE31-C2H5OH
- Alcohol
- 0~5 ppm
- Read More
![Electrochemical Alcohol Module ZE30-C2H5OH](/d/pic/newpic/ze30-c2h5oh.jpg)
Electrochemical Alcohol Module ZE30-C2H5OH
- Alcohol
- 0~5 ppm
- Read More
![Hydrogen Leak Detection Sensor Module ZE21-H2](/d/pic/newpic/ze21-cs.jpg)
Hydrogen Leak Detection Sensor Module ZE21-H2
- H2 hydrogen gas
- 0~20000ppm
- Read More
![Battery Leak Detection Module ZE21-CS/CO for Electric Vehicle](/d/pic/newpic/ze21-cs.jpg)
Battery Leak Detection Module ZE21-CS/CO for Electric Vehicle
- CO, Battery leakage comprehensive gas
- 0~1000ppm
- Read More
![Electrochemical Detection Module ZE12A](/d/pic/newpic/ze12a.jpg)
Electrochemical Detection Module ZE12A
- CO, SO2, NO2, O3
- CO (0-10ppm), SO2 (0-1ppm), NO2 (0-1ppm), O3 (0-1ppm)
- Read More
![Electrochemical Detection Module ZE11](/d/pic/newpic/ze11.jpg)
Electrochemical Detection Module ZE11
- benzene,dimethyl benzene,ethylene oxide,chloro ethylene and vinyl benzene etc.
- (0~100)ppm
- Read More
![Electrochemical HCHO Formaldehyde Sensor Module ZE08-CH2O](/d/pic/newpic/ze08-ch2o.jpg)
Electrochemical HCHO Formaldehyde Sensor Module ZE08-CH2O
- CH2O, HCHO, Formaldehyde
- 0~5ppm
- Read More
![Electrochemical Hydrogen Sensor Module ZE07-H2](/d/pic/newpic/ze07-h2.jpg)
Electrochemical Hydrogen Sensor Module ZE07-H2
- H2 hydrogen gas
- 0~30000ppm
- Read More
![Electrochemical CO Sensor Module ZE07-CO](/d/pic/newpic/ze07-co.jpg)
Electrochemical CO Sensor Module ZE07-CO
- carbon monoxide CO gas
- 0~500ppm
- Read More
![EC Hazardous Toxic Gas Detection Sensor Module ZE03](/d/pic/newpic/ze03.jpg)
EC Hazardous Toxic Gas Detection Sensor Module ZE03
- CO,O2,NH3,H2S,NO2,O3,SO2, CL2,HF,H2,PH3,HCL, etc.
- See manual
- Read More
![Electrochemical Detection Module ZE03G](/d/pic/newpic/ze03.jpg)
Electrochemical Detection Module ZE03G
- CO, H2S, NH3, CL2, SO2, NO2, O2 and other gases
- See manual
- Read More
![ZPHS01 Multi-in-One Sensor Module (HCHO version)](/d/pic/newpic/zphs01-%E7%94%B2%E9%86%9B.jpg)
ZPHS01 Multi-in-One Sensor Module (HCHO version)
- CO2, PM2.5, CH2O, VOC, Temperature, Humidity
- CO2: 0-5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%)
- Read More
![ZPH02 Particles and VOC Sensor](/d/pic/newpic/zph02.jpg)
ZPH02 Particles and VOC Sensor
- PM2.5
- VOC is 5 level Output
- Read More
![ZPH01B Particles and VOC Sensor](/d/pic/newpic/zph01b.jpg)
ZPH01B Particles and VOC Sensor
- PM2.5
- VOC is 4 level Output
- Read More
![ZM03 Digital MEMS Digital alcohol module](/d/pic/newpic/mems.jpg)
ZM03 Digital MEMS Digital alcohol module
- Alcohol
- 0-50ppm
- Read More
![ZM01 MEMS VOC Gas Sensor Module](/d/pic/newpic/mems.jpg)
ZM01 MEMS VOC Gas Sensor Module
- VOC
- 0-5ppm
- Read More
![ZP201 Refrigerant gas detection module](/d/pic/newpic/zp201.jpg)
ZP201 Refrigerant gas detection module
- Refrigerant gas R32
- Alarm value 5000ppm
- Read More
![ZP14 Combustible Gas Detection Sensor Module](/d/pic/newpic/zp14.jpg)
ZP14 Combustible Gas Detection Sensor Module
- Natural gas,CH4
- 0-5000PPM,Resolution 50PPM
- Read More
![ZP13 Smoke Sensor Module](/d/pic/newpic/zp13-mp2.jpg)
ZP13 Smoke Sensor Module
- C3H8、smoke
- Output A signal switching value output
- Read More
![ZP07 Air-Quality Detection Module](/d/pic/newpic/zp07-mp503.jpg)
ZP07 Air-Quality Detection Module
- formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, smoke of cigarette, essence &etc.
- Output 0-3 grade pollution signal
- Read More
![ZP04 Combustible Gas Detection Module](/d/pic/newpic/zp04.jpg)
ZP04 Combustible Gas Detection Module
- Natural gas,CH4
- 1%-25%LEL
- Read More
![ZP01-MP503 Air-Quality Detection Module](/d/pic/newpic/zp01-mp503.jpg)
ZP01-MP503 Air-Quality Detection Module
- formaldehyde, benzene, carbon monoxide, hydrogen,alcohol, ammonia, smoke of cigarette, essence
- Output 0-3 grade pollution signal
- Read More
![MH-742B Combustible Gas Sensor](/d/pic/newpic/mh-742b.jpg)
MH-742B Combustible Gas Sensor
- Combustible gas
- 0~100% Vol optional
- Read More
![MH-441D NDIR Infrared Methane CH4 Sensor](/d/pic/newpic/mh-410d-ch4.jpg)
MH-441D NDIR Infrared Methane CH4 Sensor
- CH4 methane
- 0~10% Vol optional
- Read More
![MH-440D NDIR Infrared CH4 Sensor](/d/pic/newpic/mh-440d.jpg)
MH-440D NDIR Infrared CH4 Sensor
- CH4
- 0~10% Vol optional
- Read More
![MH-712B Infrared CO2 Gas Sensor](/d/pic/newpic/mh-712b.jpg)
MH-712B Infrared CO2 Gas Sensor
- CO2
- 0~5% Vol optional
- Read More
![MH-711A Infrared CO2 Gas Sensor](/d/pic/newpic/mh-711a.jpg)
MH-711A Infrared CO2 Gas Sensor
- CO2
- 0~5% Vol optional
- Read More
![MH-411D NDIR Infrared CO2 Sensor](/d/pic/newpic/mh-411d.jpg)
MH-411D NDIR Infrared CO2 Sensor
- CO2
- 0~10% Vol optional
- Read More
![MH-410D NDIR Infrared CO2 Sensor](/d/pic/newpic/mh-410d.jpg)
MH-410D NDIR Infrared CO2 Sensor
- CO2
- 0~10% Vol optional
- Read More
![MH-Z19E NDIR CO2 Module](/d/pic/newpic/mh-z19e.jpg)
MH-Z19E NDIR CO2 Module
- CO2
- 400~10000ppm optional
- Read More
![MH-Z1911A NDIR CO2 Module](/d/pic/newpic/mh-1911a.jpg)
MH-Z1911A NDIR CO2 Module
- CO2(Carbon dioxide)
- 400~10000ppm optional
- Read More
![MH-Z19D NDIR CO2 Module](/d/pic/newpic/mh-z19d.jpg)
MH-Z19D NDIR CO2 Module
- CO2
- 400~10000ppm optional
- Read More
![MH-Z19C NDIR CO2 Module](/d/pic/newpic/mh-z19c.jpg)
MH-Z19C NDIR CO2 Module
- CO2
- 400~10000ppm optional
- Read More
![MH-Z19B NDIR CO2 Module](/d/pic/newpic/mh-z19b.jpg)
MH-Z19B NDIR CO2 Module
- CO2
- 400~10000ppm optional
- Read More
![MH-V1512A NDIR CO2 Sensor for Automotive](/d/pic/newpic/mh-v1512a.jpg)
MH-V1512A NDIR CO2 Sensor for Automotive
- CO2
- 400~10000ppm optional
- Read More
![MH-Z1311A NDIR CO2 Module](/d/pic/newpic/mh-z1311a.jpg)
MH-Z1311A NDIR CO2 Module
- CO2
- 0~10000ppm optional
- Read More
![MH-Z16 Infrared CO2 Gas Module](/d/pic/newpic/mh-z16.jpg)
MH-Z16 Infrared CO2 Gas Module
- CO2
- 400~10000ppm optional
- Read More
![MH-Z14B NDIR CO2 Module](/d/pic/newpic/mh-z14b.jpg)
MH-Z14B NDIR CO2 Module
- CO2
- 400~10000ppm optional
- Read More
![MH-Z14A NDIR CO2 Module](/d/pic/newpic/mh-z14a.jpg)
MH-Z14A NDIR CO2 Module
- CO2
- 400~10000ppm optional
- Read More
![ZRD16 PIR Motion Sensor Module](/d/pic/newpic/zrd16.jpg)
ZRD16 PIR Motion Sensor Module
- Induction signal
- Read More
![ZRD-09 PIR Motion Sensor Module](/d/pic/newpic/zrd09.jpg)
ZRD-09 PIR Motion Sensor Module
- Induction signal
- Read More
![RD-913FB5 Pyro-electric Flame sensor](/d/pic/newpic/rd-913fb5.jpg)
RD-913FB5 Pyro-electric Flame sensor
- Flame signal
- Read More
![RD-913FB4 Pyro-electric Flame sensor](/d/pic/newpic/rd-913fb4.jpg)
RD-913FB4 Pyro-electric Flame sensor
- Flame signal
- Read More
![RD-913FB3 Pyro-electric Flame sensor](/d/pic/newpic/rd-913fb3.jpg)
RD-913FB3 Pyro-electric Flame sensor
- Flame signal
- Read More
![RD-913FB2 Pyro-electric Flame sensor](/d/pic/newpic/rd-913fb2.jpg)
RD-913FB2 Pyro-electric Flame sensor
- Flame signal
- Read More
![RD-913FB1 Pyro-electric Flame sensor](/d/pic/newpic/rd-913fb1.jpg)
RD-913FB1 Pyro-electric Flame sensor
- Flame signal
- Read More
![RDB226S Digital PIR Pyroelectric Infrared Sensor](/d/pic/newpic/rdb-226.jpg)
RDB226S Digital PIR Pyroelectric Infrared Sensor
- human body induction
- Read More
![RDB226 Digital Pyroelectric Infrared Sensor](/d/pic/newpic/rdb-226.jpg)
RDB226 Digital Pyroelectric Infrared Sensor
- human body induction
- Read More
![RDB224 Digital Pyroelectric Infrared Sensor](/d/pic/newpic/rdb-224.jpg)
RDB224 Digital Pyroelectric Infrared Sensor
- human body induction
- Read More
![RDB223 Digital Pyroelectric Infrared Sensor](/d/pic/newpic/rdb-223.jpg)
RDB223 Digital Pyroelectric Infrared Sensor
- human body induction
- Read More
![RPTA-646 Quad-element Pyroelectric Infrared Sensor](/d/pic/newpic/rpta-646.jpg)
RPTA-646 Quad-element Pyroelectric Infrared Sensor
- human body induction
- Read More
![RPTA-628 Pyroelectric Infrared Sensor](/d/pic/newpic/rd-626w.jpg)
RPTA-628 Pyroelectric Infrared Sensor
- human body induction
- Read More
![RD-626W PIR Pyroelectric Infrared Sensor](/d/pic/newpic/rd-626w.jpg)
RD-626W PIR Pyroelectric Infrared Sensor
- human body induction
- Read More
![RD-624 PIR Pyroelectric Infrared Sensor](/d/pic/newpic/rd-624.jpg)
RD-624 PIR Pyroelectric Infrared Sensor
- human body induction
- Read More
![RD-623 Pyroelectric Infrared Sensor](/d/pic/newpic/rd-623.jpg)
RD-623 Pyroelectric Infrared Sensor
- human body induction
- Read More
![MC119 Catalytic Flammable Gas Sensor](/d/pic/newpic/mc119.jpg)
MC119 Catalytic Flammable Gas Sensor
- hydrogen, acetylene, gasoline, VOC such as alcohol, ketone, benzene.
- 0-100%LEL Anti-explosion Mark:ExdibⅠ
- Read More
![MC109 Catalytic Flammable Gas Sensor](/d/pic/newpic/mc109.jpg)
MC109 Catalytic Flammable Gas Sensor
- hydrogen,ethyne,gasoline,VOC such as alcohol,ketone,benzene in industrial occasion
- 0-100%LEL
- Read More
![MC115 Catalytic Flammable Gas Sensor](/d/pic/newpic/mc115.jpg)
MC115 Catalytic Flammable Gas Sensor
- Combustible gases such as industrial natural gas,LPG, coal gas and alkanes
- 0-100%LEL
- Read More
![MC114/MC114C Catalytic Flammable Gas Sensor](/d/pic/newpic/mc114-114c.jpg)
MC114/MC114C Catalytic Flammable Gas Sensor
- Combustible gases such as industrial natural gas,LPG, coal gas and alkanes
- 0-100%LEL Anti-explosion Mark:ExdibⅠ
- Read More
![MC113/ MC113C Catalytic Flammable Gas Sensor](/d/pic/newpic/mc113-113c.jpg)
MC113/ MC113C Catalytic Flammable Gas Sensor
- Combustible gases such as industrial natural gas,LPG, coal gas and alkanes
- 0-100%LEL(Anti-explosion Mark:ExdibⅠ)
- Read More
![MC112/MC112C/MC112D Catalytic Flammable Gas Sensor](/d/pic/newpic/mc112.jpg)
MC112/MC112C/MC112D Catalytic Flammable Gas Sensor
- Combustible gases such as industrial natural gas,LPG, coal gas and alkanes
- 0-100%LEL(Anti-explosion Mark:ExdibⅠ)
- Read More
![MC226A Catalytic Flammable Gas Sensor](/d/pic/newpic/mc226a.jpg)
MC226A Catalytic Flammable Gas Sensor
- natural gas, liquefied petroleum gas, coal gas combustible gas, methane, propane
- 0-100%LEL
- Read More
![MC107B Catalytic Flammable Gas Sensor](/d/pic/newpic/mc107b.jpg)
MC107B Catalytic Flammable Gas Sensor
- Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![MC106B Catalytic Flammable Gas Sensor](/d/pic/newpic/mc106b.jpg)
MC106B Catalytic Flammable Gas Sensor
- Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![MC106 Catalytic Flammable Gas Sensor](/d/pic/newpic/mc106.jpg)
MC106 Catalytic Flammable Gas Sensor
- Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![MC101B Catalytic Flammable Gas Sensor](/d/pic/newpic/mc101b.jpg)
MC101B Catalytic Flammable Gas Sensor
- Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![MC227D Catalytic Flammable Gas Sensor](/d/pic/newpic/mc227d.jpg)
MC227D Catalytic Flammable Gas Sensor
- Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![MC107 Catalytic Flammable Gas Sensor](/d/pic/newpic/mc107.jpg)
MC107 Catalytic Flammable Gas Sensor
- Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![MC105 Catalytic Flammable Gas Sensor](/d/pic/newpic/mc105.jpg)
MC105 Catalytic Flammable Gas Sensor
- Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![MC101 Catalytic Flammable Gas Sensor](/d/pic/newpic/mc101.jpg)
MC101 Catalytic Flammable Gas Sensor
- Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on
- 0-100%LEL
- Read More
![ME4-ETO Ethylene Oxide Gas Sensor](/d/pic/newpic/me4-eto.jpg)
ME4-ETO Ethylene Oxide Gas Sensor
- C2H4O
- 0-20ppm, Max 100ppm
- Read More
![ME4-SO2 Sulfur Dioxide Gas Sensor](/d/pic/newpic/me4-so2.jpg)
ME4-SO2 Sulfur Dioxide Gas Sensor
- SO2
- 0-20ppm, Max 200ppm
- Read More
![ME4-H2S Hydrogen Sulfide Gas Sensor](/d/pic/newpic/me4-h2s.jpg)
ME4-H2S Hydrogen Sulfide Gas Sensor
- H2S
- 0-100ppm, Max 500ppm
- Read More
![ME4-NO2 Nitrogen Dioxide Gas Sensor](/d/pic/newpic/me4-no2.jpg)
ME4-NO2 Nitrogen Dioxide Gas Sensor
- NO2
- 0-20ppm, Max 150ppm
- Read More
![ME4-NH3 Ammonia Gas Sensor](/d/pic/newpic/me4-nh3.jpg)
ME4-NH3 Ammonia Gas Sensor
- NH3
- 0-50ppm, Max 200ppm
- Read More
![ME4-H2 Hydrogen Gas Sensor](/d/pic/newpic/me4-h2.jpg)
ME4-H2 Hydrogen Gas Sensor
- H2
- 0-1000ppm, Max 2000ppm
- Read More
![ME4-CO Carbon Monoxide Gas Sensor](/d/pic/newpic/me4-co.jpg)
ME4-CO Carbon Monoxide Gas Sensor
- CO
- 0-1000ppm, Max 1500ppm
- Read More
![ME4-Cl2 Chlorine Gas Sensor](/d/pic/newpic/me4-cl2.jpg)
ME4-Cl2 Chlorine Gas Sensor
- CL2
- 0-20ppm, Max 100ppm
- Read More
![ME4-CO-E4 Carbon Monoxide Gas Sensor](/d/pic/newpic/me4-co-e4.jpg)
ME4-CO-E4 Carbon Monoxide Gas Sensor
- CO
- 0-1000ppm, Max 2000ppm
- Read More
![ME3-HCN Hydrogen Cyanide Sensor](/d/pic/newpic/me3-hcn.jpg)
ME3-HCN Hydrogen Cyanide Sensor
- HCN
- 0-100ppm, Max 150ppm
- Read More
![ME3-NO2 Electrochemical Gas Sensor](/d/pic/newpic/me3-no2.jpg)
ME3-NO2 Electrochemical Gas Sensor
- NO2
- 0-20ppm, Max 150ppm
- Read More
![ME3-H2S Hydrogen Sulfide Gas Sensor](/d/pic/newpic/me3-h2s.jpg)
ME3-H2S Hydrogen Sulfide Gas Sensor
- H2S
- 0-100ppm, Max 500ppm
- Read More
![ME3-CL2 Gas Sensor](/d/pic/newpic/me3-cl2.jpg)
ME3-CL2 Gas Sensor
- CL2
- 0-10ppm, Max 100ppm
- Read More
Help you compare our sensors
Table Overview for Winsen Product
Unsure which sensor to choose, please leave your information or email us sales@winsensor.com
Modle | Detection principle | Characteristics | Target gas | Detection range | Size |
---|---|---|---|---|---|
![]() US1010 |
Ultrasound | Good consistency, Real-time response | O2 | 20.5%~95.6% | |
![]() MH-Z9041A |
TDLAS | Resistance to water vapor, no poisoning, Response to CH4 gas only, no response to other gases | Methane CH4 | 3-100%LEL (can be customized) | 76.5mmX21mmX14.1mm |
![]() MEs-CO |
Electrochemical | Low consumption, High precision | CO Carbon Monoxide Gas | 0~1000ppm | |
![]() WS-30 |
Current-voltage test | 300mm×300mm×200mm | |||
![]() WSUS-CGL |
Ultrasonic | Low pressure absorption, No mechanical wear, Good repeatability | CH4 methane, Natural Gas, LPG Gas and other combustible gas | ||
![]() ZS13 |
Semiconductor, Module | Fully calibrated, Wide power supply voltage range, from 2.2V to 5.5V, Digital output, standard I²C signal | Temperature and Humidity | ||
![]() ZRP820 |
Infrared principle | Excellent anti-interference ability, able to effectively eliminate false alarm sources; | |||
![]() ZRP370 |
Infrared principle | Adopt large field of view angle, high detection rate, and low microphone effect sensor | Ø56mm*H21.5mm | ||
![]() ZRP320 |
Infrared principle | High detection rate, and low microphone effect sensor | Hydrocarbon combustion | Ø50mm*H21.5mm | |
![]() WPCK89 |
High Pressure, Adapt to harsh environments | ||||
![]() WPAS12 |
Independent intellectual property rights sensor design | ||||
![]() MP511D |
Semiconductor | High selectivity, fast response, good anti-interference | Refrigerant gas | 200~10000ppm | |
![]() MH-T4041A |
NDIR | High sensitivity, high resolution, fast response time | Hydrocarbon flammable gases | 0~10% Vol optional(refer to sheet 2) | Φ20mm×21.7mm |
![]() ZP16-A |
Semiconductor | High sensitivity, Excellent long-term stability | Formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, smoke of cigarette, essence &etc | VOC:0-2.000mg/m3 CO2:350-2000ppm CH2O:0-1.000mg/m3 | 24×20×15mm(L×W×H) |
![]() MC21B |
Catalytic | Bridge output voltage in linear; Fast response | Combustible gas | 0~100 | |
![]() ZM106-VOC |
MEMS | Small size, Low power consumption | VOC, Ethanol, formaldehyde, toluene and other organic volatiles | 0~10mg/m3 | |
![]() ZEH100 |
High temperature resistance; Fast response; High precision | CO, H2, VOC, Smoke, Temperature | |||
![]() ZMT500-A |
Infrared temperature measurement | Non-contact sensor, does not touch the bottom of the pot | |||
![]() ZE33 |
Electrochemical | Sound and light alarm output, and PWM digital signal output mode | CO, CH4 | ||
![]() MH-L1141A-U-100L |
Laser spectral absorption | High Sensitivity and resolution, low power consumption, small size | Methane(CH4) | 0~100%LEL | |
![]() MC33J |
Catalytic | The bridge output is linear, quick response | H2 | 0~100 | |
![]() MP810 |
Semiconductor | High sensitivity, fast response speed | H2 | 100~3000ppm | |
![]() MH-T7042A |
NDIR | High sensitivity, high resolution, low power consumption | Combustible gas(CH4) | 0~100%VOL optional | Φ51×65mm |
![]() ZE610-H2 |
Electrochemical | High sensitivity, low power consumption, long lifespan | Hydrogen gas (H2) | 0~5000ppm | |
![]() MPv-820 |
Semiconductor | High sensitivity, fast response speed | H2 | 100~3000ppm | |
![]() MEv-GH01 |
Electrochemical | Low consumption, high precision, high sensitivity | H2 | 0~2000ppm | |
![]() ZE809 |
Electrochemical | Small size, High stability, high anti-interference | Stench, odor | 0~100 OU | Φ22mm * 30.5mm |
![]() ZE808 |
Electrochemical | Small size, High stability, high anti-interference | Styrene(C8H8) | 0 ~ 10 PPM | Φ22mm * 30.5mm |
![]() ZE807 |
Electrochemical | Small size, High stability, high anti-interference | CS2 | 0 ~ 10 PPM | Φ22mm * 30.5mm |
![]() ZE806-C2H6S2 |
Electrochemical | Small size, High stability, high anti-interference | C2H6S2 | 0 ~ 10 PPM | Φ22mm * 30.5mm |
![]() ZE805-C2H6S |
Electrochemical | Small size, High stability, high anti-interference | dimethyl sulfide, C2H6S | 0-10ppm | Φ22mm * 30.5mm |
![]() ZE804-CH4S |
Electrochemical | High stability, high anti-interference | Methyl Mercaptan, CH4S | 0~10 PPM | Φ22mm * 30.5mm |
![]() ZE803-H2S |
Electrochemical | Small size, High stability, high anti-interference | H2S | 0 ~ 10 PPM | Φ22mm * 30.5mm |
![]() ZE802-C3H9N |
Electrochemical | Small size, High stability, high anti-interference | C3H9N | 0 ~ 10 PPM | Φ22mm * 30.5mm |
![]() ZE801-NH3 |
Electrochemical | Small size, High stability, high anti-interference | NH3 | 0 ~ 50 PPM | Φ22mm * 30.5mm |
![]() MPn-4C |
Semiconductor | High sensitivity to CH4 gas, Excellent anti-interference ability | CH4, Methane, Natural gas, marsh gas | 300~10000ppm (methane, natural gas) | |
![]() Anti-intrusion Sensor |
Infrared pyroelectricity | Life form |
Detection distance:3m Temperature:-55~125℃ |
||
![]() ZHMT101 |
Infrared thermopile NDIR | Life form |
Detection field of view range:0.6*1.4*0.6m CO2:400~5000ppm Temperature:-55~125℃ |
||
![]() ZH401 |
Photoelectric conversion | Light | 1500~6000lx | ||
![]() ZH101 |
Total reflection of light | Water & Light |
Rainfall:7*7mm(Rainfall detection area) Lighting directly above:1000~50000lx(Light intensity detection range) Front light:1000~100000lx(Light intensity detection range) Temperature:-40~85℃ Humidity:0~100%RH |
||
![]() Alcohol Detection Sensor |
Electrochemistry | Alcohol | 0~440mg/100ml(0~2mg/L) | ||
![]() ZW-HC101 |
Electrochemistry | Coolant | 0.01~20 uS/cm | Coolant Conductivity | |
![]() ZPH07 |
Infrared light scattering | Aerosol | 0~10000μg/m³ | ||
![]() ZEQH-101 |
Planar semiconductor NDIR | CO, CO2, VOC, temperature, pressure |
CO:0~1000ppm CO2:400~10000ppm VOC:200~10000ppm Pressure:0 ~130kPa Temperature:-40℃~200℃ |
||
![]() ZC401 |
Catalytic combustion | Natural gas, liquefied gas, coal gas, alkanes and other flammable gases | 0~100%LEL | ||
![]() ZMHS10 |
Mie scattering principle, NDIR, MOS, Temperature sensing circuit, humidity sensing material and so on | PM2.5, CO2, AQS, Temperature and humidity |
PM2.5:0~1000μg/m³ CO2:400~10000ppm AQS:CO: 1~5000ppm, NOx: 0~10ppm, NH3: 1~300ppm Temperature:-40~125℃ Humidity:0~100%RH |
||
![]() ZRP330 |
Infrared principle | Fast response and low power consumption | Hydrocarbon combustion | ||
![]() MRT-313 |
Infrared | TO-39 metal package, Specific perspective | |||
![]() ZW-RCl101 |
Electrochemical | Low power consumption, high precision, linear output, easy calibration and good stability. | |||
![]() FR08-H0A |
MEMS thermal principle | Modular design, New generation of MEMS sensor chip | |||
![]() MR007 |
Hot wire | Increased stability, high accuracy, high sensitivity, great linearity and repeatabililty | CH4 methane C3H8 propane, combustible gas, natural gas, coal gas, LPG gas | 0~100 LEL | |
![]() MEu-CO |
Electrochemical | Excellent repeatability and stability | Carbon monoxide(CO) | 0~1000ppm | |
![]() ZE730-CO |
Electrochemical | High temperature resistance, fast response, low power consumption, high precision, long life | Carbon Monoxide Gas | 0~1000ppm | |
![]() ZE08B-CH2O |
Electrochemical | High sensitivity &resolution, Low power consumption | CH2O, HCHO, Formaldehyde | 0~1.6ppm | |
![]() ZE40-TVOC |
Electrochemical | High sensitivity, high resolution | TVOC | 0~5 ppm | |
![]() ZE08K-CH2O |
Electrochemical | High sensitivity &resolution, Low power consumption, Long life | CH2O, HCHO, Formaldehyde | 0~5ppm | |
![]() ME3-CS2 |
Electrochemical | Low consumption,High precision | CS2 | 0~100ppm | |
![]() ME3-C3H9N |
Electrochemical | Low consumption,High precision | C3H9N | 0~100ppm | |
![]() ME3-C2H6S2 |
Electrochemical | Low consumption,High precision | C2H6S2 | 0~100ppm | |
![]() ME3-C2H6S |
Electrochemical | Low consumption,High precision | C2H6S | 0~100ppm | |
![]() ME3-CH4S |
Electrochemical | Low consumption,High precision | CH4S | 0~100ppm | |
![]() ME3-C8H8 |
Electrochemical | Low consumption,High precision | C8H8 | 0~100ppm | |
![]() ME3-C2H3Cl |
Electrochemical | Low consumption,High precision | C2H3Cl (chloroethylene) | 0~20ppm | |
![]() ZC61 |
MEMS | MEMS process,Intelligent algorithms | Hydrogen (H2) | 0-40000ppm | |
![]() ZPS20 |
Semiconductor | High sensitivity,Excellent long-term stability | Formaldehyde, benzene, VOC, Temperature, Relative humidity | 0~10mg/m3 | |
![]() RDA223-F |
Pyroelectric effect | High-precision AD signal process,Differential signal input mode, anti-interference ability | |||
![]() ZE25A-O3 |
Module, electrochemical | Portable O3 detector, air-quality monitor device, Ozone disinfection cabinet, smart home device, etc. | O3 | 0~2ppm | |
![]() ZPH05 |
Principle of optical contrast | Accurately identify different particles,Output the number of particles | Micro-dust | 24.52×24.22×8.3 (mm) | |
![]() GMV-2021B |
MEMS | All solid state, lightweight, low power consumption, long life, excellent anti-interference capability | hydrogen H2 gas leakage | 0.1~1000ppm(H2) | |
![]() ZRT510 |
NDIR | High sensitivity, high resolution, fast response | R454B, R32, R290, Refrigerant | 75.4*57*21.5 mm (without connecting cable) | |
![]() RDA223 |
pyroelectric effect | High-precision AD signal process,Differential signal input mode, anti-interference ability | |||
![]() ZI01 |
PID | High sensitivity and resolution; Small sizes; | VOCs | ø23.3mm*32.3mm (Profile diameter * Profile height) | |
![]() ZP16 |
Semiconductor,Modle | High sensitivity,Excellent long-term stability | Formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, smoke of cigarette, essence &etc. | 0-10mg/m3 | |
![]() WPCH04 |
Piezoresistive, Ceramic | ||||
![]() WPCH01 |
Piezoresistive, Ceramic | ||||
![]() WPAS01 |
MEMS | Package:SOP8, Wide Pressure Range:-40°~125° | |||
![]() WPAS02 |
MEMS | Package:SOP6 , Wide Pressure Range:-20°~80° | |||
![]() ZP211 |
Module,semiconductor | High sensitivity,fast response,strong anti-interference ability | Refrigerant gas R290 | 25×34×14.1mm(L×W×H) | |
![]() ZH10-VHT |
Laser spectral absorption | Good consistency;Real time response;Accurate data; | PM2.5,VOC,Temperature,Humidity | 38×35×12mm(L×W×H) | |
![]() ZH10-F |
Laser spectral absorption | Good consistency;Real time response;Accurate data; | PM1.0,PM2.5,PM10 | 0-1000 μg/m³ | 38×35×12mm(L×W×H) |
![]() ZH09 |
Laser | Good consistency,Real time response,Accurate data | PM1.0,PM2.5,PM10 | 0-100 μg/m³:±15μg/m³ 101-1000 μg /m³: ± 15% Reading (Test Condition: 25 ± 2 ℃, 50 ± 10%RH, Grimm, Cigarette, GBT18801-2015 | 47×37×12.2mm(L×W×H) |
![]() MED-O2-LA |
Electrochemical | Low consumption,High precision | O2 | ||
![]() WPCK81 |
Piezoresistive | ||||
![]() WPCK05 |
Diffused Silicon, piezoresistance | ||||
![]() WPAK70 |
Diffused Silicon | ||||
![]() ZP101 |
Semiconductor | Fast response, support serial communication | Food burnt gas | 820~1300(10ppm alcohol) (20℃-26℃/30%RH~70%RH) | 43.0mm×26.0mm×15.9mm (L×W×H) |
![]() ZE510-CH2O |
Electrochemical | High sensitivity, high resolution, low power consumption, long service life | CH2O, HCHO, Formaldehyde | 0~5ppm | |
![]() MEu-H2S |
Electrochemical | Excellent repeatability and stability | Hydrogen Sulfide(H2S) | 0~100ppm | |
![]() UE-NH3 |
Electrochemical | Long acting, Work life 5 years | Ammonia NH3 | 0~100ppm | |
![]() ZS21 |
Semiconductor, Module | Fully calibrated, Wide power supply voltage range, from 2.0V to 5.5V,Digital output, standard I²C signal | Temperature and Relative Humidity | ||
![]() MH-L9043A |
Laser spectral absorption | Good consistency, Fast response, High precision, Long life | CH4 | 3~20%LEL | 66mm*19mm*15.8mm |
![]() CMV-2021D |
Catalytic combustion effect | The bridge output is linear,Quick response | hydrogen H2 gas | 0~100 %LEL | |
![]() WHT30 |
MEMS capacitive humidity sensor | High accuracy ±3.0% RH and ±0.5℃,Wide power supply voltage range, from 2.0V to 5.5V | Environment relative humidity,temperature | ||
![]() ZH10 |
Laser scattering principle | Good consistency,Miniature size,Low power consumption,Compatible with VOC and temperature and humidity output,RESET compliant | PM2.5,VOC,Temperature,Humidity | 38×35×12mm(L×W×H) | |
![]() MEu-2CO |
Electrochemical | Excellent repeatability and stability | Carbon monoxide(CO) | 0~500ppm,Max Range 1000ppm | |
![]() MH-Z1542B |
non-dispersive infrared (NDIR) | High sensitivity, high resolution, fast response,UART output | Refrigerant | 0~5.00% Vol | 32.9x22.3x11.9mm |
![]() RPFA913CG |
pyroelectric effect | 5.0um detection band;TO-5 package, single channel, voltage mode;Low microphone effect, large FOV, high detection rate;Detection band measurement of flame signal; | |||
![]() RPFA913CF |
pyroelectric effect | 4.48um detection band;TO-5 package, single channel, voltage mode;Low microphone effect, large FOV, high detection rate;Detection band measurement of flame signal; | |||
![]() RPFA913CE |
pyroelectric effect | 4.4um detection band;TO-5 package, single channel, voltage mode;Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal; | |||
![]() RPFA913CD |
pyroelectric effect | 4.3um detection band;TO-5 package, single channel, voltage mode;Low microphone effect, large FOV, high detection rate;Detection band measurement of flame signal; | |||
![]() RPFA913CC |
pyroelectric effect | 3.8um detection band;TO-5 package, single channel, voltage mode;Low microphone effect, large FOV, high detection rate;Detection band measurement of flame signal; | |||
![]() MH-441D |
NDIR | High sensitivity, high resolution, fast response,Output method: UART, analog voltage signal | Refrigerant,R32,R454B,R410A,R134A | 0~5%VOL | Φ20×22.4mm |
![]() ME2-CO-Φ14x5 |
Electrochemical | Low consumption,High precision | CO | 0~1000ppm | |
![]() ZH30/ZH32 |
Mie scattering principle | Lin interface, good accuracy and real time response; 0.3µm Minus resolution. For automotive air conditioner, in-vehicle air quality | PM1.0,PM2.5,PM10 | 0-1000μg/m³ | 74.6×53×27mm(L×W×H) |
![]() ZM102 |
Semiconductor, MEMS technology | low power consumption, miniaturized module, Intelligent Algorithm, for vehicle HVAC, air ventilation | CO/HC、NOx、NH3 | ||
![]() MEu-2O2 |
Electrochemical | Low power consumption, high precision | O2 | 0~25% VOL | |
![]() ZPHS01C |
Module, electrochemical, semiconductor VOC sensor, laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor | This module integrates Electrochemical formaldehyde, Semiconductor VOC sensor, Laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor. | PM2.5, CO2, CH2O, TVOC,Temperature&Humidity | CO2: 400~5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%) | 62.5mm (L) x 61mm(W) x 25mm(H) |
![]() WPBH01 |
Piezoresistive | Ceramic sensitive film with high overload capacity,Laser calibration for zero and full scale | φ18.0×11.8 mm | ||
![]() WPAH01 |
Piezoresistive | Ceramic sensitive film with high overload capacity,Laser calibration for zero and full scale | |||
![]() MH-441D-454B |
NDIR | High sensitivity, high resolution, fast response,Output method: UART, analog voltage signal... | Refrigerant,R454B | 0~5%VOL | Φ20×22.4mm |
![]() MEu-O2 |
Electrochemical | No pollution, long life, high precision, high sensitivity, Excellent repeatability and stability | Oxygen(O2) | 0~25% VOL | |
![]() US1000 |
Ultrasonic oxygen sensor | Good consistency,Real-time response,High precision | oxygen concentration and flow in oxygen | (Concentration)21%~95.6%/(Flow)0~10L/min | 120mm*30mm*30mm(L*W*H) |
![]() RDA226 |
High-precision AD signal process,Differential signal input mode, anti-interference ability | human body induction | |||
![]() RTGA71 |
TO-46 metal package,High sensitivity | CO2 | |||
![]() ZQ02-O3 |
Semiconductor,Modle | Mini size&Quick response | Ozone | 10-1000PPB | 22.5 mm×24 mm×27 mm(L×W×H) |
![]() ME2-O2-Ф20 |
Electrochemical | Low consumption,High precision | O2 | 0~25%Vol | |
![]() ME3-CH2O |
Electrochemical | Low consumption,High precision,High sensitivity | CH2O, HCHO, Formaldehyde | 0~10ppm | |
![]() ZE07-CH2O |
Electrochemical,Modle | High sensitivity & resolution& Good stability | CH2O, HCHO, Formaldehyde | 0~5ppm | |
![]() MP135 |
Semiconductor | High sensitivity; Quick response and resume; | H2,Alcohol, CO |
H2:10~500ppm Alcohol:5~500ppm CO:10~500ppm |
|
![]() WSP2110 |
Semiconductor | High sensitivity to organic gases such as toluene, benzene, methanal; quick response and recovery; low power consumption, simple detection circuit, good stability and long life. | toluene, methanal, benzene, alcohol, acetone &etc. | 1~50ppm | |
![]() WSP5110 |
Semiconductor | High sensitivity to Refrigerants; quick response and resume; low power consumption, simple detection circuit, good stability and long life. | Refrigerant, benzene, alcohol &etc. | 10~1000ppm | |
![]() 4R-PID |
High sensitivity; Wide detection range | VOC,Energy≤10.6eV Volatile Gases | 0~10000 ppm | ||
![]() ZE40B-TVOC |
Electrochemical | High sensitivity, high resolution, low power consumption, long lifespan,RESET compliant | Alcohol | 0~2 ppm | |
![]() ME3-HCL |
Electrochemical | Low consumption,High precision | HCL | 0~20ppm | |
![]() ZPH01 |
IR | High sensitivity, good stability for long time, calibrated before delivery, built-in heater to snift air automatically. | PM2.5 | 15000 particles /283ml | 59.47×44.5×20mm(LxWxH) |
![]() MH-741A |
NDIR | High sensitivity, high resolution, low power consumption | CH4 methane, natural gas, combustible gas | 0~100%VOL optional | Φ44×61mm |
![]() ZC01 |
Catalytic | CH4 methane gas | |||
![]() ZC02 |
Catalytic | CH4 methane gas | |||
![]() ZP05 |
Semiconductor | High sensitivity, wide voltage input, strong anti-jamming capability, good stability and shock resistance | Natural gas | 1~25%LEL | 25.4×21.7×11mm(L×W×H) |
![]() ZP06 |
Semiconductor | High sensitivity, wide voltage input, strong anti-jamming capability, good stability and shock resistance | Natural Gas | Diameter33mm*17.5mm | |
![]() ZP10 |
Semiconductor | High sensitivity, wide voltage input, strong anti-jamming capability, good stability and shock resistance | Natural gas, LPG, Manufactured Gas | 1~25%LEL | Φ23×60.5mm |
![]() MR513 |
Hot-wire gas sensor | High sensitivity, large signal output | C2H5OH, alcohol, ethanol | Φ12mm×10mm | |
![]() MD61 |
Thermal conduction | Good re-peatability and reliable performance | Methane, hydrogen, inert gases | 0~100% | 19×9.5×14 |
![]() MD62 |
Good reproducibility and reliable performance | CO2 | 19×9.5×14 | ||
![]() MG-812 |
Semiconductor | Small sizes, low power-consumption, high sensitivity and good selectivity | CO2 | 0~ 10000ppm CO2 | |
![]() ZPHS01B |
Module | See Manul | CO2. PM2.5. CH2O. O3. CO. TVOC. NO2. Temperature. Humidity | See Manul | 135 x 50 x 26.2mm (L x W x H) |
![]() ZW03 |
Electrochemical | Low power consumption,high accuracy ,linear output, easy calibration and excellent stability. | pH water | 40×25mm | |
![]() MW-TDS101 |
High precision, fast response, good stability, small size and easy installation. | TDS | 0-2000ppm | ||
![]() ZW-TDS102 |
Digital signal output | Low power, high precision, linear output, convenient calibration and good stability | TDS | 0-2000μs/cm | 58X38mm |
![]() ZE29A-C2H5OH |
Electrochemica,Modle | High-precision and high-sensitivity,Blow interruption alarm,High stability and strong anti-interference ability | Alcohol | 0~1.0 mg/l | 85*33*18mm |
![]() FR20 |
MEMS thermal principle | High sensitivity,Very low pickup flow,High Accuracy | Measure the mass flow of gases in the pipe, dry and non-corrosive gases | 150/200/300 | |
![]() FR06 |
MEMS thermal principle | High sensitivity,Very low pickup flow,High Accuracy | Flow monitoring of pipeline gas medium | 150/200/300 | |
![]() FR03 |
MEMS thermal principle | High sensitivity,Very low pickup flow,High Accuracy | Mass gas flow monitoring of gas medium in the pipe | 0.2/0.3/0.4/0.5SLM | |
![]() FR03H |
MEMS thermal principle | High sensitivity,Very low pickup flow,High Accuracy | Mass gas flow monitoring of gases in the pipe | 5L/min @20℃ 101.325kPa | |
![]() F1032 |
Principles of thermodynamics | Latest MEMS Sensor chip technology,High accuracy, quick response, good repeatability | Flow monitoring of pipeline gas medium | 20、35、50、100、150、 200 SLM | |
![]() F1031V |
Principles of thermodynamics | High accuracy, quick response, good repeatability | Mass gas flow measurement in the flow channel | 100, 150, 200, 300SLM | |
![]() F1031 |
Principles of thermodynamics | Mass gas flow measurement in the flow channel | |||
![]() F1022 |
Thermodynamic Principles | High accuracy, quick response, good repeatability | Flow detection of the gas medium in the flow channel | 5、10、15、20 SLM | |
![]() F1013 |
Principles of thermodynamics | High accuracy, quick response, good repeatability | Gas mass measurement and control in the flow channel | 50、100、200、500、1000、2000sccm | |
![]() F1012 |
Principles of thermodynamics | High accuracy, quick response, good repeatability | Mass gas measurement and control in the flow channel | 50、100、200、500、1000、2000sccm | |
![]() ZH08 |
Laser | Good consistency,Real time response,RESET compliant | PM1.0,PM2.5,PM10 | 58.5×44.5×14.8mm(L×W×H) | |
![]() ZH07 |
Laser | Good consistency, Real time response, Low power consumption, RESET compliant | particulate matters PM1.0, PM2.5, PM10 | 0-1000μg/m³ | 48×40×12.5mm(L×W×H) |
![]() ZH06-IV |
Laser | Good consistency,Real time response,Accurate data,RESET compliant | PM1.0,PM2.5,PM10 | 0-1000μg/m³ | 47×37×12.2mm(L×W×H) |
![]() ZH06-III |
Laser | Good consistency,Real time response,Accurate data,RESET compliant | PM1.0,PM2.5,PM10 | 0-1000μg/m³ | 47×37×12.6mm(L×W×H) |
![]() ZH06-II |
Laser | Good consistency,Real time response,Accurate data,RESET compliant | PM1.0,PM2.5,PM10 | 0-1000μg/m³ | |
![]() ZH06-Ⅰ |
Laser | Good consistency,Real time response,Accurate data,RESET compliant | PM1.0,PM2.5,PM10 | 0-1000μg/m³ | 47×37×12.2mm(L×W×H) |
![]() ZH03B |
Laser | Good consistency, Real time response | PM1.0,PM2.5,PM10 | 0-1000μg/m³ | 50x32.4x21mm(LxWxH) |
![]() ZPH04 |
IR | Good Stability for long time,Easy to install and use | PM2.5 | 59.5×44.5×20mm(L×W×H) | |
![]() ZPH04B |
IR | Good Stability for long time,Easy to install and use | PM2.5 | 0-500ug/m3 | 59×45×20mm(L×W×H) |
![]() ZPH03 |
IR | Good Stability for Long Time,Low Consumption,Good Anti-interference Performance | PM2.5 | 4 ~ 500ug/m³ | 46.0×32.0×18.3mm(L×W×H) |
![]() WPCK62 |
Diffused Silicon, piezoresistance | ||||
![]() WPCK07 |
Diffused Silicon, piezoresistance | ||||
![]() WPCK03 |
Diffused Silicon, piezoresistance | ||||
![]() WPAK69 |
Diffused Silicon | ||||
![]() WPAK68 |
Diffused Silicon | ||||
![]() WPAK67 |
Diffused Silicon | ||||
![]() WPAK66 |
Diffused Silicon | ||||
![]() WPAK65 |
Diffused Silicon | ||||
![]() WPAK64 |
Diffused Silicon | ||||
![]() WPAK63J |
Diffused Silicon | ||||
![]() WPAK63 |
Diffused Silicon | ||||
![]() MQ-7B |
Semiconductor | Good sensitivity to CO | CO | 10-500ppm | φ16.7×9.4 |
![]() MQ316 |
Semiconductor | High sensitivity to C2H5OH、H2S、CH3SH | Mouth odor:C2H5OH、H2S、CH3SH | C2H5OH(5-200ppm) | φ9.4×8 |
![]() MQ303B |
Semiconductor | High sensitivity to C2H5OH and quick response and resume | C2H5OH | 20-500ppm | φ9.4×6 |
![]() MQ138 |
Semiconductor | High sensitivity to C7H8、CH3COCH3、C2H5OH、CH2O | C7H8、CH3COCH3、C2H5OH、H2 | 5~500ppm | φ19×24.2 |
![]() MQ137 |
Semiconductor | Good sensitivity to NH3 | NH3 | 5-500ppm | φ19×24.2 |
![]() MQ136 |
Semiconductor | Good sensitivity to H2S | H2S | 1-200ppm | φ19×24.2 |
![]() MQ135 |
Semiconductor | Good sensitivity to toxic gas | Air pollution:NH3、sulfide、benzene series steam | NH3、C7H8、H2、Smoke(10~1000ppm) | φ19×24.2 |
![]() MQ131-L |
Semiconductor | Good sensitivity to O3 | O3 | 10-1000ppb | φ16×13.9 |
![]() MQ131-H |
Semiconductor | Good sensitivity to O3 | O3 | 10-1000ppm | φ19×24.2 |
![]() MQ-9B |
Semiconductor | Good sensitivity to CO | CO,CH4 | CO(10-500ppm),CH4(300-10000ppm) | φ16.7×9.4 |
![]() MQ-8 |
Semiconductor | Good sensitivity to H2 | H2 hydrogen gas | 100-1000ppm | φ19×24.2 |
![]() MQ-6 |
Semiconductor | Good sensitivity to flammable gas(Especially C3H8) | LPG,CH4 | CH4、C3H8(300-10000ppm) | φ19×24.2 |
![]() MQ-5B |
Semiconductor | Good sensitivity to flammable gas(Especially C3H8) | Propane C3H8, LPG gas, methane CH4 | CH4、C3H8(300-10000ppm) | φ16.7×9.4 |
![]() MQ-5 |
Semiconductor | Good sensitivity to flammable gas(Especially C3H8) | Propane C3H8, LPG gas, methane CH4 | CH4、C3H8(300-10000ppm) | φ19×24.2 |
![]() MQ-4B |
Semiconductor | High sensitivity to CH4 and strong anti-interference ability | methane CH4, natural gas, flammable gas | 300-10000ppm | φ16.7×9.4 |
![]() MQ-4 |
semiconductor | High sensitivity to CH4 and strong anti-interference ability | methane CH4, natural gas, flammable gas | CH4(300-10000ppm) | φ19×24.2 |
![]() MQ-3B |
semiconductor | High sensitivity to alcohol gas and can resistant to the interference of gasoline, smoke and vapour. | C2H5OH | 25-500ppm | φ17×9.4 |
![]() MS-Z3 |
Made of polymer humidity-sensitive material | 1、Wide humidity detected rang;2、Fast response;3、Small Humidity hysteresis error;4、Simple manufacture;5、Easy integration;6、Low cost | Environment relative humidity,temperature | ||
![]() ZS11 |
It is equipped with special ASIC sensor chip, high-performance semiconductor silicon-based capacitive humidity sensor and a standard on-chip temperature sensor,it uses standard I ² C output signal format. | 1、 Fully calibrated;2、Wide power supply voltage range, from 2.0V to 5.5V;3、Digital output, standard I²C signal;4、Quick response and strong anti-interference ability;5、 Excellent long-term stability under high humidity condition | Environment relative humidity,temperature | ||
![]() ZS05 |
Temperature and humidity detection | 1、Low cost, Low power consumption, Small sizes;2、High sensitivity;3、Standard IIC digital interface;4、RESET compliant | Environment relative humidity,temperature | ||
![]() ZS03 |
Temperature and humidity detection | 1.Low cost, Low power consumption, Small sizes;2.Single wire serial interface, High sensitivity; 3.Calibrated, digital output;4.RESET compliant | Environment relative humidity,temperature | ||
![]() WHT20 |
MEMS capacitive humidity sensor | 1、High accuracy ±3.0% RH and ±0.5℃;2、Wide power supply voltage range, from 2.0V to 5.5V;3、SMD package suitable for reflow soldering;4、Quick response and strong anti-interference ability;5、Excellent long-term stability under high humidity condition | Environment relative humidity,temperature | ||
![]() MRTD-3011 |
Seebeck principle | 1, TO-39 package, small view. 2, I2C interface, internal temperature self-compensation. 3. Signal sampling speed can be set: 16 order speed can be adjusted. 4, good stability | temperature | -20-250℃ | TO39 9.05X4.5 |
![]() RTTA71 |
Seebeck principle | High sensitivity, fast response, Good stability, high NTC precision | temperature | -30-125℃ | TO46 5.4x2.10 |
![]() MRT511 |
Seebeck principle | High sensitivity, fast response, Good stability, high NTC precision | temperature | -30-100℃ | TO39 9.14X4.5 |
![]() MRT311S |
Seebeck principle | High sensitivity, fast response, Good stability, NTC calibration free | temperature | -30-100℃ | TO46 5.4x2.10 |
![]() MRT311 |
Seebeck principle | High sensitivity, fast response, Good stability, high NTC precision | temperature | -30-100℃ | TO46 5.4x2.9 |
![]() MW-RCl101 |
It is polarographic type residual chlorine water quality detection sensor | High precision, low power consumption, linear output, Analog signal output | Solution | 0~20 mg/L | |
![]() MW-O101 |
It is a galvanic battery type dissolved oxygen water quality detection sensor. | Low power consumption, high precision, linear output, no need to replace the breathable membrane, no need to replace the electrolyte. | Solution | 0~20 mg/L | |
![]() MW-O201 |
It is polarographic type dissolved oxygen water quality detection sensor. | Quick response, good stability, high precision, long life and easy maintenance. | Liquid | 0~20 mg/L | |
![]() ZW-NH101 |
Electrochemical type ammonia nitrogen water quality detection sensor | Fast response, high sensitivity, low power consumption, linear output, Analog signal output | Liquid | 0~1000 mg/L | |
![]() MW-pH101 |
It is an electrochemical PH water quality detecting sensor | Low power consumption, wide linear range, excellent repeatability and stability. | Liquid | 1~14 | |
![]() MW-ORP101 |
A primary battery type ORP water quality detection sensor. | High precision, fast response, good stability, small size, low power consumption, easy to carry | Liquid | -2000 mV ~﹢2000 mV | |
![]() ZCE04B |
Module,catalytic, electrochemical | The detection of toxic and harmful gas and combustible gas in special places will give an alarm when the concentration exceeds the standard to remind people to evacuate | CH4(1%LEL), CO(1ppm), H2S(1ppm), O2(0.1%LEL) | 0-100%LEL ,0-1000ppm ,0-100ppm ,0-30%LEL | 41×41×21.6 |
![]() ZC13 |
Module,catalytic | Complete device development of household gas leak alarm. | methane CH4, natural gas, flammable gas | 1%-25%LEL,Resolution100ppm | 25×21.1×18.2 |
![]() ZC08 |
Module,catalytic | Complete device development of household gas leak alarm. | methane CH4, natural gas, flammable gas | 1%-20%LEL,Resolution100ppm | 24×18×13 |
![]() ZC08-H2 |
Module,catalytic | For complete device development of household hydrogen gas leak alarm | H2 hydrogen | 0-20000ppm,Resolution100ppm | 24×18×19.5 |
![]() ZC05 |
Module,catalytic | Complete device development of household gas leak alarm. | Natural gas, methane CH4 gas | 1%-25%LEL,Resolution100ppm | 25×21.1×17.2 |
![]() ZEHS04 |
Module, electrochemical | Urban atmospheric environmental monitoring; Unorganized emissions of pollution monitoring at factory sites; Portable instruments, air quality monitoring equipment, and smart home equipment. | CO, SO2, NO2, O3 (Scalable PM2.5, PM10, Temperature, Humidity) | See manual | 12cm*10cm*6cm (L*W*H) |
![]() ZE31-C2H5OH |
Module, electrochemical | Alcohol detector, vehicle-mounted detector | Alcohol | 0~5 ppm | 17.1x19.2x4.5mm |
![]() ZE30-C2H5OH |
Module, electrochemical | Alcohol detector, vehicle-mounted detector | Alcohol | 0~5 ppm | 17.1x19.2x4.5mm |
![]() ZE27-O3 |
Module, electrochemical | Portable O3 detector, air-quality monitor device, Ozone disinfection cabinet, smart home device, etc. | O3 | 0~10ppm | 17.1x19.2x4.5mm |
![]() ZE25-O3 |
Module, electrochemical | Portable O3 detector, air-quality monitor device, Ozone disinfection cabinet, smart home device, etc. | O3 | 0~10ppm | 23x25.5x4.4mm |
![]() ZE21-H2 |
Module, electrochemical | Hydrogen leakage and leak detection | H2 hydrogen gas | 0~20000ppm | 25.43x22.33x7.3mm |
![]() ZE21-CS |
Module, electrochemical | UART output. For battery leak detection in electric vehicle battery boxes, new energy storage and other occasions. | CO, Battery leakage comprehensive gas | 0~1000ppm | 25.43x22.33x7.3mm |
![]() ZE18-CO |
Module, electrochemical | Household CO gas alarm, smart home devices. | CO | 0~500ppm | 61x14x4.4mm |
![]() ZE16-CO |
Module, electrochemical | Household CO gas alarm, smart home devices. | CO | 0~500ppm | 40x17.30x13.8 |
![]() ZE16B-CO |
Module, electrochemical | Development of household CO gas alarm Detection of CO concentration at residential occasions | CO | 0~500ppm | 28x117mm |
![]() ZE15-CO |
Module, electrochemical | Household CO alarm gas, smart home devices. | CO | 0~500ppm | 25.4x22.4x18.3mm |
![]() ZE14-O3 |
Module, electrochemical | Ozone disinfection cabinet, smart home devices, etc. | O3 | 0~100ppm | 22x26x18.2mm |
![]() ZE12A |
Module, electrochemical | City atmospheric environmental monitoring , enterprise environment monitoring, Factory area unorganized emission monitoring, emergency monitoring, environment evaluation monitoring, Portable gas detector, various gas detection equipment and smart home ap | CO, SO2, NO2, O3 | CO (0-10ppm), SO2 (0-1ppm), NO2 (0-1ppm), O3 (0-1ppm) | Φ39×44 mm |
![]() ZE11 |
ZE11 Module, electrochemical | Petroleum and chemical industry, environment protection filed, detection of benzene,dimethyl benzene,ethylene oxide,chloro ethylene and vinyl benzene | benzene,dimethyl benzene,ethylene oxide,chloro ethylene and vinyl benzene etc. | (0~100)ppm | Ø32mm*31.2mm |
![]() ZE08-CH2O |
Module,electrochemical | Portable detector, air-quality monitor, air cleaner, air renewal system, air conditioner, smart home. | CH2O, HCHO, Formaldehyde | 0~5ppm | 23x25x4.4mm |
![]() ZE07-H2 |
Module, electrochemical | Supply UART output, analog voltage output and various of output way | H2 hydrogen gas | 0~30000ppm | 25.4x22.4x18.6mm |
![]() ZE07-CO |
Module, electrochemical | Supply UART output, analog voltage output and various of output way | carbon monoxide CO gas | 0~500ppm | 25.4x22.4x18.3mm |
![]() ZE03 |
Module, electrochemical | Supply UART output and analog voltage output; Use for portable and fixed gas detector, various gas detection equipment and occasion. | CO,O2,NH3,H2S,NO2,O3,SO2, CL2,HF,H2,PH3,HCL, etc. | See manual | ø23.5mm*24.5mm |
![]() ZE03G |
Module, electrochemical | Portable and fixed gas detector, various gas detection equipment and situation. | CO, H2S, NH3, CL2, SO2, NO2, O2 and other gases | See manual | ø23.5mm*24.5mm |
![]() ZPHS01 |
Module, electrochemical, semiconductor VOC sensor, laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor | This module integrates Electrochemical formaldehyde, Semiconductor VOC sensor, Laser particle sensor, NDIR CO2 sensor and temperature & humidity sensor. | CO2, PM2.5, CH2O, VOC, Temperature, Humidity | CO2: 0-5000ppm; PM2.5: 0-1000μg/m³; CH2O: 0-1.6ppm; VOC: 4 level; Temperature: 0-65℃ (Accuracy±0.5℃); Humidity: 0-100%RH (Accuracy±3%) | Length×Width: 72x61 |
![]() ZPH02 |
IR | Dust sensor and VOC sensor integrated, the sensor has been aged, debuged, calibrated before delivery and has good consistency and high sensitivity | PM2.5 | VOC is 5 level Output | 59.5×44.5×17 |
![]() ZPH01B |
IR | Dust sensor and VOC sensor integrated, the sensor has been aged, debuged, calibrated before delivery and has good consistency and high sensitivity | PM2.5 | VOC is 4 level Output | 59.5×44.5×20 |
![]() ZM03 |
Module,semiconductor, MEMS | High sensitivity and small size, and adopts I2C digital signal output mode | Alcohol | 0-50ppm | 5×5×1.55 |
![]() ZM01 |
Module,semiconductor,MEMS | High sensitivity and small size, and adopts I2C digital signal output mode | VOC | 0-5ppm | 5×5×1.55 |
![]() ZP201 |
Module,semiconductor | Air conditioning and refrigeration system refrigerant leakage detection | Refrigerant gas R32 | Alarm value 5000ppm | 25×34×14.1 |
![]() ZP14 |
Module,semiconductor | Complete device development of household gas leak alarm. | Natural gas,CH4 | 0-5000PPM,Resolution 50PPM | 25×21.1×15 |
![]() ZP13 |
Module,semiconductor | High sensitivity,excellent long term stability, calibrated before shipment 10 seconds to 5 minutes with auto-preheating function Faulty auto-check | C3H8、smoke | Output A signal switching value output | 24.1×20.1×15.6 |
![]() ZP07 |
Module,semiconductor | High sensitivity,excellent long term stability, calibrated before shipment 10 seconds to 3 minutes with auto-preheating function Faulty auto-check | formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, smoke of cigarette, essence &etc. | Output 0-3 grade pollution signal | 24×20×16 |
![]() ZP04 |
Module,semiconductor | Complete device development of household gas leak alarm. | Natural gas,CH4 | 1%-25%LEL | 25.4×21.7×22.6 |
![]() ZP01-MP503 |
Module,semiconductor | Calibrated before shipment, (10S-4Min)with auto-preheating function, faulty auto-check | formaldehyde, benzene, carbon monoxide, hydrogen,alcohol, ammonia, smoke of cigarette, essence | Output 0-3 grade pollution signal | 24×20×16 |
![]() MH-742B |
non-dispersive infrared (NDIR) principle | 1.High sensitivity, high resolution, low power consumption; 2.Widely used for industrial field instrumentation, industrial-process control and safety protection | Combustible gas | 0~100% Vol optional | Φ39×44 mm |
![]() MH-441D |
non-dispersive infrared (NDIR) principle | 1. High sensitivity, high resolution, fast response;2.Output method: UART, analog voltage signal;3. Temperature compensation, excellent linear output;4. Excellent stability, Long lifespan;5. Anti-poisons, anti-vapor interference;6. Can replace catalytic | CH4 methane | 0~10% Vol optional | Φ20 mm×22.2 mm |
![]() MH-440D |
non-dispersive infrared (NDIR) principle | 1. High sensitivity, high resolution, fast response;2. Output method: UART, analog voltage signal;3. Temperature compensation, excellent linear output;4. Excellent stability, Long lifespan;5. Anti-poisons, anti-vapor interference;6. Can replace catalytic | CH4 | 0~10% Vol optional | Φ20×22.6mm |
![]() MH-712B |
non-dispersive infrared (NDIR) principle | 1. High Sensitivity and resolution, low power consumption, fast response;2. Output method: UART, analog voltage output signal, etc. 3. Temperature compensation, excellent linear output;4. Good stability;5. Long lifespan;6. Anti-poisons, anti-vapor interfe | CO2 | 0~5% Vol optional | Φ39×44 mm |
![]() MH-711A |
non-dispersive infrared (NDIR) principle | Detect combustible gas concentration matching with flame-proof marked detector in area 1&2 explosive environments which mix of ⅡA, ⅡB, ⅡC and T1-T6 flammable gases, vapors and air | CO2 | 0~5% Vol optional | Φ44 mm×61 mm |
![]() MH-411D |
non-dispersive infrared (NDIR) principle | 1. High sensitivity, high resolution, low power consumption, Fast response time; 2. Output method: UART, analog voltage signal; 3.Temperature compensation, excellent linear output; 4. Long lifespan; 5. Excellent stability;6. Anti-poisons, anti-vapor inter | CO2 | 0~10% Vol optional | Φ20 mm×22.2 mm |
![]() MH-410D |
non-dispersive infrared (NDIR) principle | 1. High sensitivity, high resolution, low power consumption, Fast response time; 2. Output method: UART, analog voltage signal; 3.Temperature compensation, excellent linear output; 4. Long lifespan;5. Excellent stability;6. Anti-poisons, anti-vapor interf | CO2 | 0~10% Vol optional | Φ20 mm×22.6 mm |
![]() MH-Z19E |
non-dispersive infrared (NDIR) principle | 1. High sensitivity, low power consumption; 2, Good stability; 3. Temperature compensation, excellent linear output; 4. Multiple output modes: UART, PWM; 5.RESET compliant | CO2 | 400~10000ppm optional | 32.9x19.7x8.6mm (LxWxH) |
![]() MH-Z1911A |
non-dispersive infrared (NDIR) principle | High sensitivity, low power consumption; Temperature compensation, excellent linear output; Multiple output modes: UART, PWM | CO2(Carbon dioxide) | 400~10000ppm optional | 32.9x19.7x8.6mm (LxWxH) |
![]() MH-Z19D |
non-dispersive infrared (NDIR) principle | 1, High sensitivity, low power consumption; 2, Good stability; 3. Temperature compensation, excellent linear output; 4. Multiple output modes: UART, PWM; 5.RESET compliant | CO2 | 400~10000ppm optional | 32.9x19.7x8.6mm (LxWxH) |
![]() MH-Z19C |
non-dispersive infrared (NDIR) principle | 1. Chamber is gold plated; 2. High sensitivity, low power consumption; 3. Good stability; 4. Temperature compensation, excellent linear output;5.RESET compliant | CO2 | 400~10000ppm optional | 32.9x19.7x8.6mm(LxWxH) |
![]() MH-Z19B |
non-dispersive infrared (NDIR) principle | CO2 | 400~10000ppm optional | 32.9x19.7x8.6mm(LxWxH) | |
![]() MH-V1512A |
non-dispersive infrared (NDIR) principle | Lin interface. Extremely low power consumption, excellent for for in-car air quality, vehicle HVAC and ventilation. | CO2 | 400~10000ppm optional | 33.02x22x9.33mm (LxWxH) |
![]() MH-Z1311A |
non-dispersive infrared (NDIR) principle | 1. The air chamber adopts electroplating treatment, waterproof and anti-corrosion 2. High sensitivity, low power consumption 3. Excellent stability 4. Temperature compensation, excellent linear output 5.RESET compliant | CO2 | 0~10000ppm optional | 32.36x19.5x11.4mm(LxWxH) |
![]() MH-Z16 |
non-dispersive infrared (NDIR) principle | Educational instruments, animal husbandry production | CO2 | 400~10000ppm optional | 57.15x34.7x14.5mm (LxWxH) |
![]() MH-Z14B |
non-dispersive infrared (NDIR) | 1. Chamber is gold plated, water-proof and anti-corrosion; 2. High sensitivity, low power consumption; 3. Good stability; 4. Temperature compensation, excellent linear output; 5. Multiple output modes: UART, PWM; 6. Long lifespan; 7. Anti-water vapor inte | CO2 | 400~10000ppm optional | 57.15x34.7x14.5mm(LxWxH) |
![]() MH-Z14A |
non-dispersive infrared(NDIR)principle | 1. Chamber is gold plated, water-proof and anti-corrosion; 2. High sensitivity, low power consumption; 3. Good stability; 4. Temperature compensation, excellent linear output; 5. Multiple output modes: UART, PWM; 6. Long lifespan; 7. Anti-water vapor inte | CO2 | 400~10000ppm optional | 57.15x34.7x14.5mm(LxWxH) |
![]() ZRD16 |
pyroelectric effect | 1、Automatic Induction;2、Photo-resistor control;3、Induction blocking time(default setting as 2s second);4、 High-level output | Induction signal | 32mm*28mm*12.3mm | |
![]() ZRD-09 |
pyroelectric effect | 1、Automatic Induction;2、Photo-resistor control;3、Two trigger modes;4、Induction blocking time;5、High-level output | Induction signal | 32mm*24mm*24mm | |
![]() RD-913FB5 |
pyroelectric effect | 1、4.45um detection band;2、TO-5 package,single channel,voltage mode;3、Low microphone effect,large FOV,high detection rate;4、Detection band measurement of flame signal | Flame signal | TO-5 9.1x4.5mm | |
![]() RD-913FB4 |
pyroelectric effect | 1、4.4um detection band;2、TO-5 package,single channel,voltage mode;3、Low microphone effect,large FOV,high detection rate;4、Detection band measurement of flame signal | Flame signal | TO-5 9.1x4.5mm | |
![]() RD-913FB3 |
pyroelectric effect | 1、5um detection band;2、TO-5 package,single channel,voltage mode;3、Low microphone effect,large FOV,high detection rate;4、Detection band measurement of flame signal | Flame signal | TO-5 9.1x4.5mm | |
![]() RD-913FB2 |
pyroelectric effect | 1、4.3um detection band;2、TO-5 package,single channel,voltage mode;3、Low microphone effect,large FOV,high detection rate;4、Detection band measurement of flame signal | Flame signal | TO-5 9.1x4.5mm | |
![]() RD-913FB1 |
pyroelectric effect | 1、3.8um detection band;2、TO-5 package, single channel, voltage mode;3、Low microphone effect, large FOV, high detection rate; 4、Detection band measurement of flame signal | Flame signal | TO-5 9.1x4.5mm | |
![]() RDB226S |
pyroelectric effect | Sensitivity, delay time, and light adjustment function | human body induction | TO-5 9.1x4.5mm | |
![]() RDB226 |
pyroelectric effect | Sensitivity, delay time, and light adjustment function | human body induction | TO-5 9.1x4.5mm | |
![]() RDB224 |
pyroelectric effect | Delay time adjustment function | human body induction | TO-5 9.1x4.5mm | |
![]() RDB223 |
pyroelectric effect | 1. High-precision AD signal process. 2. Differential signal input mode,anti-interference ability. 3. Wide voltage power supply and power consumption. 4. Digital TTL signal outp | human body induction | TO-5 9.1x4.5mm | |
![]() RPTA-646 |
pyroelectric effect | Quad element, used for the design of ceiling products; direction detection can be realized with appropriate circuit. | human body induction | TO-5 9.1x4.5mm | |
![]() RPTA-628 |
pyroelectric effect | View the manual | human body induction | TO-5 9.1x4.5mm | |
![]() RD-626W |
pyroelectric effect | analog output, good anti-electromagnetic interference performance | human body induction | TO-5 9.1x4.5mm | |
![]() RD-624 |
pyroelectric effect | analog output, high sensitivity, anti-interference, and excellent signal to noise ratio. | human body induction | TO-5 9.1x4.5mm | |
![]() RD-623 |
pyroelectric effect | analog output, large detection range, high sensitivity, anti-interference, and excellent signal to noise ratio. | human body induction | TO-5 9.1x4.5mm | |
![]() MC119 |
catalytic combustion | "Bridge output voltage in linear, fast response, good repeatability and selectivity " | hydrogen, acetylene, gasoline, VOC such as alcohol, ketone, benzene. | 0-100%LEL Anti-explosion Mark:ExdibⅠ | 19×9.5×14 |
![]() MC109 |
catalytic combustion | "Bridge output voltage in linear, fast response, good repeatability and selectivity " | hydrogen,ethyne,gasoline,VOC such as alcohol,ketone,benzene in industrial occasion | 0-100%LEL | φ12×9.5 |
![]() MC115 |
catalytic combustion | "Bridge output voltage in linear, fast response, good repeatability and selectivity " | Combustible gases such as industrial natural gas,LPG, coal gas and alkanes | 0-100%LEL | φ6×6.5 |
![]() MC114/MC114C |
catalytic combustion | "Bridge output voltage in linear, fast response, good repeatability and selectivity " | Combustible gases such as industrial natural gas,LPG, coal gas and alkanes | 0-100%LEL Anti-explosion Mark:ExdibⅠ | 114: 19×9.5×14; 114C: 14×8×10 |
![]() MC113 |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as industrial natural gas,LPG, coal gas and alkanes | 0-100%LEL(Anti-explosion Mark:ExdibⅠ) | 113:19×9.5×14 113C:14×8×10 |
![]() MC112/MC112C/MC112D |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as industrial natural gas,LPG, coal gas and alkanes | 0-100%LEL(Anti-explosion Mark:ExdibⅠ) | 112C:14×8×10;MC112/112D:19×9.5×14 |
![]() MC226A |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | natural gas, liquefied petroleum gas, coal gas combustible gas, methane, propane | 0-100%LEL | φ12×9.5 |
![]() MC107B |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12×10 |
![]() MC106B |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12×9.5 |
![]() MC106 |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12×9.5 |
![]() MC101B |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12.2×8.5 |
![]() MC227D |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12.4×10.3 |
![]() MC107 |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12×10 |
![]() MC105 |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12×9.5 |
![]() MC101 |
catalytic combustion | Bridge output voltage in linear, fast response, good repeatability and selectivity | Combustible gases such as domestic natural gas,LPG,coal gas,CH4,C3H8 and so on | 0-100%LEL | φ12×9.5 |
![]() ME4-ETO |
Electrochemical | Detection of ethylene oxide in petroleum and petrochemical, pharmaceutical and environmental protection fields | C2H4O | 0-20ppm, Max 100ppm | φ32×14.5 |
![]() ME4-SO2 |
Electrochemical | Detection of sulfur dioxide in industrial and environmental protection fields | SO2 | 0-20ppm, Max 200ppm | φ32×14.5 |
![]() ME4-H2S |
Electrochemical | Detection of hydrogen sulfide in industrial, underground mining and environmental protection fields | H2S | 0-100ppm, Max 500ppm | φ32×14.5 |
![]() ME4-NO2 |
Electrochemical | Detection of nitrogen dioxide in industrial, underground mining and environmental protection fields | NO2 | 0-20ppm, Max 150ppm | φ32×14.5 |
![]() ME4-NH3 |
Electrochemical | Detection of ammonia in industrial and environmental protection fields | NH3 | 0-50ppm, Max 200ppm | φ32×14.5 |
![]() ME4-H2 |
Electrochemical | Detection of hydrogen in industrial and environmental protection fields | H2 | 0-1000ppm, Max 2000ppm | φ32×14.5 |
![]() ME4-CO |
Electrochemical | Petroleum and petrochemical, metallurgy, mining and other industrial sites and environmental protection fields | CO | 0-1000ppm, Max 1500ppm | φ32×14.5 |
![]() ME4-Cl2 |
Electrochemical | Detection of chlorine gas in chemical, pharmaceutical production and environmental protection fields | CL2 | 0-20ppm, Max 100ppm | φ32×14.5 |
![]() ME4-CO-E4 |
Electrochemical | Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring | CO | 0-1000ppm, Max 2000ppm | φ32×14.5 |
![]() ME3-HCN |
Electrochemical | Detection of hydrogen cyanide in petroleum and petrochemical, pharmaceutical production and environmental protection fields | HCN | 0-100ppm, Max 150ppm | φ20×16.4 |
![]() ME3-NO2 |
Electrochemical | Detection of nitrogen dioxide in industrial, underground mining and environmental protection fields | NO2 | 0-20ppm, Max 150ppm | φ20×16.4 |
![]() ME3-H2S |
Electrochemical | Detection of hydrogen sulfide in industrial, underground mining and environmental protection fields | H2S | 0-100ppm, Max 500ppm | φ20×16.4 |
![]() ME3-CL2 |
Electrochemical | Detection of chlorine gas in chemical, pharmaceutical production and environmental protection fields | CL2 | 0-10ppm, Max 100ppm | φ20×16.4 |
- 0086-371-67169097
- sales@winsensor.com
- Mon - Fri 9am - 6pm
ARE YOU LOOKING FOR SENSOR
Not sure which sensor is right?
Get a free initial consultation right now
WHAT WE DO
Product Knowledge
Product